Monitor the electrical conductivity of water sources using an EC meter

2026년 04월 10일 10시 27분 53초

Electrical conductivity (EC) is a fundamental parameter in water quality assessment. This index reflects the ability of a solution to conduct electricity through dissolved ions, including metal salts and inorganic compounds such as NaCl, KCl, nitrates, or phosphates

The higher the ion concentration, the greater the electrical conductivity, which in turn increases the EC value. Therefore, EC is used as an indirect indicator of total dissolved solids (TDS), helping to identify the condition of the water source before conducting more detailed analyses.

EC in water quality control

EC provides quantitative data on the level of ion presence in a solution. This index allows for monitoring variations in water quality over time or between different areas within the same system.

In operation, EC is used to:

- Detect abnormal changes in water composition and assess the level of salt and mineral accumulation.

- Provide a basis for selecting additional measurements such as pH, heavy metals, or hardness.

Prepare samples and equipment before measurement

The stability of the results depends on the sample conditions and the state of the equipment. Water samples should be contained in clean plastic cups to minimize interference from conductive materials.

Before measurement, the equipment should be checked and calibrated using standard solutions as recommended by the manufacturer. The electrodes must be clean and free of impurities.

During the measurement process:

- Immerse the probe so that the sensor is completely covered.

- Gently shake to remove any air bubbles on the surface.

- Record the result when the displayed value stabilizes.

The effect of temperature on the results of measuring the electrical conductivity of water

Temperature directly affects the movement of ions in solution, thereby changing the EC value. As temperature increases, conductivity increases; as temperature decreases, EC decreases.

Many devices incorporate automatic temperature compensation (ATC) mechanisms to bring results back to standard conditions. For devices without this function, the sample temperature must be determined and adjustments made according to the technical instructions.

Another definition is electrode. The electrode is the component that comes into direct contact with the sample and directly affects the sensitivity of the measurement. After each use, it should be rinsed with distilled water to remove any impurities adhering to the surface.

Minimize mechanical contact with the sensing area to maintain surface properties. Impurities that accumulate over time can cause inaccurate results if not regularly cleaned.

EC measuring devices should be stored in a dry, stable environment and protected from corrosive agents. Using the correct accessories and following the technical instructions will help maintain the device's operational status.

Related topics:

Does water conduct electricity? Q&A with experts at EMIN

Why is EC conductivity meter calibration necessary?

What is the safe temperature for electrical wires?

Measuring EC conductivity and common errors

Limits of conductivity index in water analysis

EC does not provide information about the specific nature of dissolved substances. Solutions with the same EC value may contain different chemical compositions.

Therefore, this index needs to be used in conjunction with other analytical methods to provide a more complete assessment of water quality.

관련 뉴스

What Is Fiber Polarity and How Do You Choose an MPO Method?
2026년 11월 14일 11시 35분 16초

Fiber polarity ensures the transmit path connects to the corresponding receive path. For MPO-based duplex channels, the selected method must remain consistent across trunks, cassettes, adapters, and patch cords.

The scent of new wood in a newly handed-over apartment: How to measure and address formaldehyde (HCHO) levels before moving in
2026년 11월 14일 10시 28분 19초

Many people refer to the pungent, acrid odor that emerges when opening a new cabinet as the "smell of new wood," assuming it will simply dissipate after a few days. In reality, however, what is being released could well be formaldehyde—a substance originating from the adhesives used in the pressed-wood panels—and our sense of smell is not a reliable enough gauge to determine the concentration levels present

Guide to Selecting a TCLP Toxicity Characteristic Leaching Procedure Shaker Configuration in Compliance with QCVN 07:2025/BNNMT and TCVN 9239:2012
2026년 11월 13일 17시 23분 39초

Regulation QCVN 07:2025/BNNMT (replacing QCVN 07:2009/BTNMT and QCVN 50:2013/BTNMT) specifies hazardous waste and sludge thresholds based on leachate concentrations. To ensure that analytical results for heavy metals and organic compounds are accepted during ISO/IEC 17025 or VIMCERTS assessments, laboratories must comply with the Toxicity Characteristic Leaching Procedure (TCLP) specified in TCVN 9239:2012, which is equivalent to US EPA Method 1311

Checking the Temperature of Paint and Coating Surfaces After Curing Using an Infrared Thermometer
2026년 11월 13일 16시 11분 22초

An infrared thermometer allows surface temperature measurement without direct contact, making it suitable for products coming out of curing ovens or surfaces that are difficult to access. However, to ensure reliable results for production quality control, it is important to understand the measurement principle and the factors that affect measurements on painted and coated surfaces.

Crowded Gyms and Yoga Studios: How to Manage Air Quality to Retain Members
2026년 11월 13일 15시 07분 40초

Around 6 or 7 in the evening, the gym becomes packed; the music drowns out the sound of heavy breathing, and the air conditioning runs at full blast behind closed doors. At first glance, everything seems fine: the room is cool, the lights are bright, and the equipment is state-of-the-art. Yet, after just a few sessions, regular members begin to feel a heavy-headedness and find themselves running out of breath more quickly eventually, they simply stop renewing their memberships. No one complains about the personal trainers or the exercise machines. The very thing that makes them feel stifled and drives them away is something entirely invisible: the air inside the room

혜택 소식 받아보기

대량 할인, 도매 가격 업데이트 및 신제품 소식을 이메일로 받아보세요.

구독하면 당사의 서비스 이용약관 및 개인정보 처리방침에 동의하는 것으로 간주됩니다.

빠른 지원

인증된 전문가에게 직접 연결