Test Currents: 1 Ma, 10 Ma, 100 Ma, 1 A, 10 A, 200 A.Each Current May Be Continuously Adjustable From 0 To 100%.
Resistance Ranges:
Current Range Resolution
200 A: 0–199.9 µΩ 0.1 µΩ
200 A: 0–199.9 µΩ 1 µΩ
10 A: 0–1999 µΩ 1 µΩ
10 A: 0–19,999 mΩ 1 µΩ
1 A: 0–19.99 mΩ 10 µΩ
1 A: 0–199.99 mΩ 10 µΩ
100 mA: 0–199.9 mΩ 100 µΩ
100 mA: 0–1999.9 mΩ 100 µΩ
10 mA: 0–1999 mΩ 1 mΩ
10 mA: 0–19.999 Ω 1 mΩ
1 mA: 0–19.99 Ω 10 mΩ
1 mA: 0–199.99 Ω 10 mΩ
For Each Test Current, Ranges Are Automatically Selected For Optimal Reading.
Measurement Principle: Four-Terminal, Kelvin-Type.
Continuous Operation Time:
At 200 A This Equipment May Be Used Continuously For Aprox. 3 Minutes Before The Thermal Protection Activates.
At 10 A Or Less, There Is Not A Limited Time For Continuous Operation.
Basic Accuracy:
R < 0.5 Mω: ± (0.50% Of Reading + 2 Uud*).
R ≥ 0.5 Mω: ± (0.20% Of Reading + 2 Uud*).
* Units Of The Least Significant Digit.
Advanced Features: Digital Direct Reading Of Very Low Resistances In The Alphanumerical Display, With Up To 4½ Digits. Very Fast And Accurate Measurements.
Termal Protection: Protects All Sensitive Components, Avoiding Any Damage Due To Overheating.
Environmental: Ip54 With Closed Lid.
Safety Class: Meets The Requirements Of Iec 61010-1.
Interface Usb. Power Supply:
Mains Or Internal Battery Powered.
Internal Battery: Rechargeable, Sealed Lead-Acid, 12 V - 7 Ah (For Up To 10 A Test Current).
Mains Supply: 220-240 V~ (For Up To 200 A Test Current).
Built-In Battery Charger: For 220-240 V~ Mains Supply.
Operating Temperature Range: -5 °C To +50 °C.
Storage Temperature Range: -25 °C To +70 °C.
Umidity Range: 95% Ur (Non Condensing).
Equipment Weight: Approx. 16 Kg.
Dimension: 502 X 394 X 190 Mm.
Available Accessories: 2 Combined Current And Potential Leads For 10 A. 2 Combined Current And Potential Leads For 200 A. 1 Power Cord. 1 Usb Cable. 1 User Guide. 1 Case For The Accessories.