CH4: 

Measurement range: 0 – 10 000 ppmv 

Accuracy: ±4 ppm 

          ±5% of reading

Repeatability: 10 ppm 

               5% of reading

C2H6:

Measurement range: 0 – 10 000 ppmv 

Accuracy: ±10 ppm 

          ±5 % of reading

Repeatability: 10 ppm 

               5% of reading

C2H4:

Measurement range: 0 – 10 000 ppmv 

Accuracy: ±4 ppm 

          ±5 % of reading

Repeatability: 10 ppm 

               5% of reading

C2H2: 

Measurement range: 0 – 5000 ppmv

Accuracy: ±0.5 ppm 

          ±5% of reading

Repeatability: 1 ppm 

               5% of reading

CO: 

Measurement range: 0 – 10 000 ppmv

Accuracy: ±4 ppm 

          ±5% of reading

Repeatability: 10 ppm 

               5% of reading

CO2: 

Measurement range: 0 – 10 000 ppmv

Accuracy: ±4 ppm 

          ±5% of reading

Repeatability: 10 ppm 

               5% of reading

H2: 

Measurement range: 0 – 5000 ppmv

Accuracy: ±15 ppm 

          ±10% of reading

Repeatability: 1 ppm 

               5% of reading

H2O: 

Measurement range: 0 – 100 ppmw

Accuracy: ±2 ppm 

          ±10% of reading

Repeatability: ±2 ppm 

               ±10 % of reading

Total gas pressure: 

Measurement range: 0–2000 hPa 

Accuracy: ±10 hPa 

          ±2% of reading

Repeatability: 10 hPa 

               5% of reading

Operating voltage: 

          OPTPSU1: 100–240 V AC, 50–60 Hz, ±10 %

          OPTPSU2: 110–220 V DC, ±10 %

Overvoltage category: III

Maximum power consumption: 500 W

Typical power consumption at +25°C (+77°F): 100 W