For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

VICTOR 4000 Double Clamp Digital Phase Meter (500V AC, 10A AC)

부가세 별도
8,040,800 VND
부가세 포함
8,684,064 VND
안전한 결제
품질 보장
간편 교환 및 반품
배송 가능

Base Conditions and Working Conditions

Influence Quantity: Base Condition/ Working Conditions

Ambient Temp: 23℃±1℃/ -10℃~40℃

Ambient Humidity: 40%~60%/ <80%

Signal Waveform:  sine wave/ sine wave

Signal Frequency:  50HZ±1HZ/ 45HZ~65HZ

Meter Working Volt: 9V±0.1V/ 9V±1V

External Electric: To be avoided

Technical data

Function: Phase, AC current, AC voltage, AC leakage current, direct test of phase sequence; transformer groups, inductive, capacitive circuit discrimination; indirect test of power factor and power

Consumption

About 35mA at most with enabled backlight, battery working continuously for about 40 hours

About 5mA with disabled backlight, battery working continuously for about 300 hours

Sampling Rate: About 3 times/second

Measurement Range

AC Voltage: 0~20V/200V/500V

AC Current: 0~200mA/2A/10A

Phase: 0~360°

Measured Signal Amplitude in Phase Test

U1-U2 phase test: 30V~500V

I1-I2 phase test: 10mA~10.00A

U1-I2 or I1-U2 phase test: 10V~500V,10mA~10.00A

Weight: 550g(with battery), clamp 170g×2, test line 250g

Test Line Length: 1.5m

Current Clamp Length: 2m

Working Temperature and Humidity: -10℃~40℃; below 80%Rh

Storage Temperature and Humidity: -10℃~60℃; below 70%Rh

Input Impedance

Input impedance for all test voltage range: 2MΩ

Input impedance when testing U1U2 phase: 40KΩ