Control Mode: Internal A8 Industrial control board
Data storage: Internal
Signal collecting mode: Automatic continuous collection
Trigger: signal
Acoustic transit time accuracy: 0.025μs
Dynamic range: 154dB
Receiver sensitivity: ≤10μv
Emission voltage(V): 65、250、500、1000 V adjustable
Data transmission: USB、MiniUsb、Wi-Fi、Bluetooth
Power Internal: Built-in lithium battery
External: 220V AC/DC
Weight: 1.36kg(lithinum battery included)
Screen: 5.7inch、high brightness TFT LCD screen
Operation Mode: Touch screen and button
Channels: 1 emitter+1 receiver
Sampling interval: 0.025μs~1638.4μs adjustable
±1677.7ms
Amplifier bandwidth: 3~450kHz
Gain error: 0.5dB
Size(mm: 210×149×60
Operational environment Temperature: -10℃~+40℃
Humidity: <90%RH
Battery time: >5h
Size(mm) 210×149×60
Operational environment Temperature -10℃~+40℃
Humidity <90%RH
Battery time >5h
U5200 ,Plane probe ,Signal wire,Waterproof case
1. Ultrasonic transmission method for testing the integrity of foundation pile (called “pile test” for short)
2. Ultrasonic-rebound combined method for testing compressive strength of concrete (called “strength test” for short);
3. Ultrasonic transmission method for testing defect and cavity in structural member (called “defect test” for short);
4. Ultrasonic flat-measured method for testing crack depth of concrete surface (called “crack test” for short)