GRAPHTEC GL240 10 채널 4.3
생산업체: GRAPHTEC Model: GL240 - 견적요구
- 연락처
Manufaturer: Ghaphtec
Model: GL240
GL240 Main unit specifications
Item |
Description |
|
|
Number of analog input channels |
10 channels |
|
|
External input/ |
Input *2 |
Trigger or Sampling (1 channel), Logic/Pulse (4 channels) |
|
Output *3 |
Alarm (4 channels) |
|
|
Sampling interval |
10 ms to 1 hour (10ms to 50ms: voltage only) *4, External signal |
|
|
Time scale of waveform display |
1sec. to 24 hour /division |
|
|
Trigger, |
Trigger action |
Start or stop capturing data by the trigger |
|
Repeat action |
Off, On (auto rearmed) |
|
|
Trigger source |
Start: Off, Measured signal, Alarm, External, Clock, Week or Time |
||
Condition Setting |
Combination: OR or AND |
||
Alarm output |
Outputs a signal when alarm condition occurs in the input signal *5 |
|
|
Pulse input |
Rotation count |
Counts the number of pulses per sampling interval and converts to rpm |
|
Accumulating |
Accumulates the number of pulses from the start of measurement |
||
Instant count |
Counts the number of pulses per sampling interval |
||
Calculation |
Between channels |
Addition, Subtraction, Multiplication, and Division for analog input |
|
Statistical |
Select two calculations from Average, Peak, Maximum, Minimum, RMS |
|
|
Search function |
Search for analog signal levels, values of logic or pulse or alarm point |
||
Interface to PC |
USB (Hi-speed), WLAN (using B-568 option) |
|
|
Storage |
Media |
SD memory card (Support SDHC, up to 32 GB), supports 2 slots *6 |
|
Saved contents |
Captured data, Setting conditions, Screen copy |
|
|
Capturing mode |
Mode: Normal, Ring, Relay |
||
Replay Data |
Replays captured data that was saved in the GL240 (in BGD or CSV format) |
|
|
Scaling (Engineering unit) function |
Measured value can be converted to the specified engineering unit |
||
Action during data capture |
• Displaying parst data (using dual display mode (Current + Past data)) |
||
Display |
Size |
4.3-inch TFT color LCD (WQVGA: 480 x 272 dots) |
|
Language |
English, French, German, Chinese, Korean, Russian, Spanish, Japanese |
|
|
Information *8 |
Waveform in Y-T with digital values, Waveform only, Digital value, Digital values |
||
Operating environment |
0 to 45 ºC, 5 to 85 % RH (non condensed) |
||
Power source |
AC adapter |
100 to 240 V AC, 50/60 Hz (1 pc of adapter is attached as standard accessory) |
|
DC power |
8.5 to 24 V DC (DC drive cable (option B-514) is required) |
|
|
Battery pack |
Mountable battery pack (battery pack (option B-517): 7.2V DC, 2900mAh) |
|
|
Power consumption *9 |
Max. 36 VA |
|
|
External dimensions (W x D x H) |
Approx.188 x 117 x 42 mm (Excluding projections) |
|
|
Weight *10 |
500 g |
|
*1
Input/Output cable for GL (option B-513) is required to connect the signal.
*2
Input signal;
· Voltage range: Up to 24V (common ground)
· Signal type: Voltage, Open collector, Contact (relay)
· Threshold: Approx. + 2.5 V (Hysteresis: Approx. 0.5V (2.5V to 3V))
*3
Output signal: Open collector (pull-up to 5V by 10kΩ resistor)
· Voltage: Max. 30V
· Current: Max. 0.5A
· Collector dissipation: Max. 0.2W
*4
Minimum interval varies by number of channels used.
*5
Output port can be specified in each input channel.
*6
4GB SD memory card is installed to slot 1 as standard accessory.
*7
Size of the capture data will be limited to 1/3 of available memory.
*8
Display mode is switched every time the dedicated key is pressed. In magnified digital value mode, the displayed channel number can be specified. In the waveform display mode, the changing of the time scale will be effective from the point of the next displayed data.
*9
Rating under maximum power consumption using the AC adapter, with LCD display on, and battery pack being
charged.
*10
Excludes AC adapter and battery pack.
Software specifications for PC
<td
Item |
Description |
|
|
Model name |
GL100_240_840-APS |
|
|
Supported OS |
Windows 10, 8.1, 8, 7, Vista (32/64-bit edition) |
|
|
Supported device |
GL840 (USB, Ethernet, WLAN), GL240 (USB, WLAN), GL100 (USB, WLAN) |
|
|
Functions |
Control the GL series, Real-time data capture, Replay data, and Data format conversion |
|
|
Supported units & channels |
Up to 1000 channels total, Up to 4 groups (number of units is limited by model) |
|
|
Settings control |
Input condition, Captuering condition, Trigger/Alarm condition, Report, etc. |
|
|
Capturing data |
Saved to PC |
Saves captured data in real time (in GBD binary or CSV format) |
|
Saved to GL unit |
Saves to the SD memory card (in GBD binary or CSV format) |
|
|
Displayed information |
Y-T waveform, Digital values, Report, X-Y graph (specified period of data, data reply only), |
||
- 품질 보증
- 공인 보증
- 집으로 배달
- 간단하게 거래하기