For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Aqualabo NC-FIX-C-00252 ACTEON 5000 COD/BOD/TOC测试套,Op path 50 mm 15 M

ModelNC-FIX-C-00252
联系我们
安全结算
品质保证
轻松更换与退货
支持配送

Transmitter ACTEON 5000

Software and features

Digital sensor: 2 inputs digital sensor RS485

2 analog input: In mode 0/4-20 mA or 0-10 V

2 relay input: Function of transfer on exit(release) TOR

                      Information of external cleaning system: swing in maintenance mode

2 analog outputs: Choice of 2 parameters programmable according to the connected sensor

                             Programming PID

2 digital outputs /relay: NO/NF customizable

                                      Instruction point: setting of the measuring range

                                      (Hysteresys / activation way) and time of activation,

                                      Command for external cleaning system

                                      Output alarm for defect material sensor

Digital output: Modbus RTU

                       Ethernet TCP IP

Data recording: Internal flash memory

                          Frequency recording: 1-120 mn

                          Recording journal of events, measure sensors.

Atmospheric pressure sensor: To compensate oxygen pression

Characteristics

Display: Backlit graphic LCD touch Screen – Size95x54 mm

Analog outputs: 0/4.00 – 20.00 mA with galvanic isolation

                          Charge max 250 W

Relay outputs: 6 A /250 V

Operating conditions: Temperature : -15°C to + 50 °C

                                   Temperature of storage/transport : -15°C to + 50°C

USB port: Unloading of the recorded data

Power/ Electrical protections: 100-240 V AC/DC 50-60 Hz

                                                - Option 9-28 V DC/DC

                                                - Electrical protection: consistent EN61010-1 :2010

Housing

Dimensions (LxHxP): 213 x 185 x 84 mm

Material: Grey ABS

Protection rating: IP 65

Front: Antireflective polyester

Containing:

- 1  ACTEON 5000 Transmitter digital dual sensors 

- 1 STACSENSE Opt path 20 mm with 15m cable

For specific range please check the attachment below!

Datasheet

Datasheet StacSense


Datasheet Transmitter digital physicochemistry ACTEON 5000


User Manual Transmitter digital physicochemistry ACTEON 5000


User Manual Transmitter digital physicochemistry ACTEON 5000_Calibration procedure STACSENSE


User Manual StacSense