For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

BalunTech BL784 冷镜露点仪 (-45℃~+90℃; 4.41%~100%RH)

联系我们
安全结算
品质保证
轻松更换与退货
支持配送

DP/FP ranges: -20℃ to +85℃, (4.41%~100%RH @20℃)

DP/FP accuracy: ±0.20℃ (calibration: -15℃ to +20℃)

DP/FP resolution: 0.01℃

DP/FP reproducibility error: ±0.05℃

Temperature range: -45℃ to +90℃

Temperature accuracy: ±0.10℃ (calibration: -10℃~60℃)

Temperature resolution: 0.01℃

Temperature reproducibility error: ±0.05℃

Working environment: -20℃ to +60℃, 10%RH to 90%RH, 101.325kPa (custom atm. is option)

Mirror temperature measurement: 4 wire PT100 1/3B

Probe material: SUS304 stainless steel

Cable material: Polyurethane material with shielding layer

Response time: Max cooling 0.8℃/s, + 15s balance time

Sampling airflow rate: 0.1~1NL/min (The volume of ventilation is inversely proportional to the dew point)

Cooling type: Peltier cooling

Output signal: Modbus RTU, USB

Power supply: 100-240VAC 35W or USB Type-C 5V/2A 10W

Ingress protection grade: IP54

Dimension: 160mm (W) x 165mm (D) x 85mm (H)

Weight: 4 kg inlcudes standard accessories


SCOPE OF DELIVERY

BL784 Chilled mirror dew point meter

Single Stage Chilled Mirror Dew Point Sensor

2 meters dew point sensor connection cable

USB2.0 into USB type-C cable

Standard AC Power cord

User manual

Factory calibration report

Carrying cas

DATASHEET


DESCRIPTION

Chilled mirror dew point meter is a precise technique for determining the water vapor content is gases by directly measuring dew point or frost temperatures. Using this technique a metal mirror is cooled until it reaches a temperature at which a thin layer of condensation begins to form on it. The dew layer is detected optically, and the mirror is held at that temperature. The mirror temperature, measures with a PRT, is an accurate indicator of the dew or frost point.

FEATURES

Dew point range -20℃ to +85℃

Accuracy to ±0.20 ℃ dew point

Dynamic balance control for contamination

Simultaneously measures dew point, temperature, relative humidity, absolute humidity, specific humidity, enthalpy, vapor pressure and volume ratio (ppmV).

Real time data logging and curve display

MAX value and MIN value are recorded

AC or alternative DC power supply

MODBUS RTU and USB communication

4 inch touch screen

APPLICATION

Reference standard in calibration lab

Inlet air measurement for engine testing

Heating ventilation and air conditioning test

Environment monitoring in clean room

Humidity control for metallurgical processes

Coating process monitoring in pharmacy

Reference humidity instruments for climatic and environmental chambers

获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款隐私政策

快速支持

直接联系认证专家