支持配送

Output Rating: 

Output Voltage : 0 to 800 V

Output Current : 0 to 25 A 

Output Power : 20 kW

Line Regulation: 

Voltage : 160 mV 

Current:  5 mA 

Load Regulation: 

Voltage : 420 mV

Current : 33 mA 

Ripple and Noise (20 Hz to 20 MHz): 

Voltage p-p : 350 mV 

Voltage rms : 150 mV

Current rms(1) : 25 mA 

Readback Resolution: 

Voltage Range: 

20 V to 99.99 V:  10 mV

100.0 V to 999.9 V:  0.1 V

1000 V to 1500 V : - 

Current Range: 

0 A to 9.999 A : 1 mA

10.00 A to 25 A : 10 mA

Programming Accuracy: 

Voltage:  ≤ 800 mV 

Current : ≤ 50 mA 

Output Response Time(2): 

Rise Time: 

Full Load : ≤ 40 ms

No Load : ≤ 10 ms

Fall Time: 

Full Load : ≤ 60 ms 

No Load : ≤ 10 s

400 AC Input: 

Nominal Input : Voltage 400 VAC

Input Range : 360 to 440 VAC

Frequency : 47 to 63 Hz

Phase 3 phase: 

Protection: 

OVP Range:  0 to 960 V 

General: 

Remote Sense Compensation:  80 V

Transient Response Time(3) : ≤ 3 ms

Command Response Time(4) : 10 ms

Efficiency(5) : 0.94

Power Factor:  > 0.7

Output Terminal Isolation : 2000 V

Inrush Current(6) : 76 A

Leakage Current : < 35 mA

I/O Interfaces:  RS232, LAN,Analog (Galvanically isolated DB25)

Analog Programming (typical): Input impedance: 1 MΩ;  Maximum input voltage 25 V;  Response time < 10 ms

Temperature Ratings: 

+ Operation: 32 ºF to 122 ºF (0 ºC to 50 ºC)

+ Storage: -4 ºF to 158 ºF (-20 ºC to 70 ºC)

Operating Humidity : < 80%

Altitude : < 2000 m

Environment : Installation category II, pollution degree 2

Dimensions (W×H×D) : 19” x 5.3” x 24.2” (482 x 132.5 x 614.7 mm)

Weight: 82 lbs (37 kg)

Standard Accessories : Test report & certificate of calibration

Regulatory Compliance: 

Safety:  Low Voltage Directive (LVD) 2014/35/EU, EN61010-1:2010 + A1:2019

Electromagnetic Compatibility:  EMC Directive 2014/30/EU, EN61326-1:2013

(1) When output power > 1.0% of full power.

(2) From 10% to 90% or from 90% to 10% of total voltage excursion

(3) Time for output voltage to recover within 0.5% ±25 mV of its rated output.

(4) Typical time required for output to begin to change following receipt of command data.

(5) At nominal line voltage and max load.

(6) Applies to rated input voltage. The inrush current only occurs when first connecting to the grid.

Datasheet

获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款和隐私政策。

快速支持

直接联系认证专家