直接联系认证专家
Sensor: electrochemical sensor
Measure range: 0~25.00% O2
Accuracy: ±2%FS
Repeatability: ±1%FS
Stability: ±1%FS/7d
Response time: T90<20s
Explosion-proof grade: Exd || CT6
Protection level: IP65
Measuring method: on-line
Display: 128×64 OLED
Key: 3 touch keys
Calibration cycle: one year (recommended)
Power supply: 24VDC
Analyzer power <15VA
consumption: RS485/RS232
Communication: 1 set,4-20mA/0-20mA/0-1V/0-5V/0-10V/ 1-5V(You can set the mode freely). The load:less than 500 Ω
Analog output: Alarm output:1 set
Switch output: Relay contact point capacity:24V DC,0.2A
Environment -10~+45°C
temperature: <90%RH
Environment humidity: 500~1000ml/min
Sample flow rate: atmospheric conditions±10% (Gas outlet
Sample gas pressure: should be atmospheric conditions)
Gas interface: 1/4-inch NPT internal thread,standard 6.5 hose joint
Sensor life: more than 2 years (normal use)
Instrument life: more than 5 years (normal use)
Weight: 2.35kg net
Installation: wall-mounted