Chauvin Arnoux RW521 反射计功率计 / RF / 微波 / 便携式
- Frequency: 1.3 to 2.7 GHz
- Power:
+Incident: 10 to +40 dBm
+Reflected: 5 to +35 dBm
- Accuracy: ± 6 %
- Use: VHF-FH Rural networks
- Impedance: 50 Ω
- Insertion loss: < 0.1 dB
- Residual S.W.R.:≤1.15
- Input and output connectors: N female
- Power supply:2 x 1.5 V batteries ; one 9 V battery for the RW 511
- Operating temperature:0 to +50°C
- Weight: approximately 1.4 kg
- Dimensions (l x h x d) : 180 x 120 x 60 mm
Description
The ORITEL RW521 directional wattmeter is designed for use during the commissioning and maintenance of telecommunications stations from 1.3 to 2.7 GHz, for rural UHF mobile telephony networks in particular.
It measures the power supplied by a transmitter in dBm and the power reflected by the "feeder-antenna" assembly in order to determine antenna suitability .
- Operation from 1.3 to 2.7 GHz
- Measurement from +5 to +40 dBm in CW mode
- Rugged and rain-proof
- Very long battery life (several months)
直接联系认证专家