CHROMA 61509 Programmable AC Power Source (6kVA)
AC Output
Number of output phases: 1 phase or 3 phase
Max power: 6kVA
Power per phase: 2kVA
Voltage
Voltage range: 0~175V/0~350V/Auto
Voltage range with 5kHz option
At 15Hz~3000Hz: 0~175V/0~350V
At 3001Hz~5000Hz: 0~115V/0~230V
Accuracy: 0.1% of RD+0.2% of FS
Resolution: 0.1V
Distortion:
< 0.3% @50/60Hz ;
< 1% @15Hz ~ 500Hz ;
1% maximum to 500Hz, add 0.5%/kHz up 2kHz
Line regulation: 0.1%
Load regulation: 0.2%
Maximum Current (Single-phase mode)
RMS: 60A/30A
Peak (CF=4): 240A/120A
Maximum Current (Per phase in three-phase mode)
RMS: 20A/10A
Peak (CF=4): 80A/40A
Frequency
Frequency range: 15Hz~2000Hz
Frequency range with 5kHz option: 15Hz~5000Hz
Accuracy: 0.01%
DC Output (Single-phase mode)
Power: 6kW
Voltage: 247.5V/495V
Current: 60A/30A
DC Output (Three-phase mode)
Power: 2kW
Voltage: 247.5V/495V
Current: 20A/10A
Input Specifications:
Voltage range: 3Ø 200-240V±10%VLN (WYE) ; 3Ø 200-240V±10%VLL (Delta)
Current (per phase): 25A Max./Phase (3Ø 200-240V±10%VLL)
Power factor: 0.97 (Typical)
Measurement
Voltage
Voltage range: 0~175V/0~350V/Auto
Voltage accuracy: 0.1% of RD+0.2% of FS
Current
Current accuracy (RMS): 0.2% of RD+0.2% of FS
Current accuracy (Peak): 0.2% of RD+0.4% of FS
Power
Accuracy: 0.2% of RD+0.4% of FS
Power Line Disturbance Simulation (PLD Simulation): LIST, PULSE, STEP functions.
Waveform Synthesis: Up to 50th order at 50/60Hz.
Harmonics Measurement: Voltage and current measurement up to the 50th order at 50/60Hz.
Programmable impedance: 0Ω+0.2mH ~ 1Ω+2mH
Efficiency: >80%(Typical)
Protection: OVP, OCP, OPP, OTP, FAN
Safety & EMC standards: CE mark
Dimensions (H x W x D): 221.5 x 425 x 680mm
Weight: 50 kg
直接联系认证专家