For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

CHROMA 66204 Digital Power Meter (4CH, 600Vrms, 20Arms, 12kW)

联系我们
安全结算
品质保证
轻松更换与退货
支持配送

Number of channels: 4

Measured parameters: V, Vpk, I, Ipk, Is, W, VA, VAR, PF, CFi, F, THD V, THD I, E

Voltage

Measurement range: 15V / 30V / 60V / 150V / 300V / 600Vrms (CF=2), 6 ranges, HV option up to 1800Vrms

Accuracy:

DC, 10Hz to 1kHz: 0.1% RD + 0.08% RNG

1kHz to 10kHz: (0.1 + 0.05 × kHz)% RD + 0.08% RNG

Harmonic accuracy:

DC, 10Hz to 1kHz: 0.1% RD + 0.08% RNG

1kHz to 10kHz: (0.1 + 0.05 × kHz)% RD + 0.08% RNG

Input impedance: 4MΩ

AC/DC Current

Measurement range: 5mA / 20mA / 50mA / 200mA / 500mA / 2A / 5A / 20Arms (CF=4)

Accuracy:

DC, 10Hz to 1kHz: 0.1% RD + 0.1% RNG

1kHz to 10kHz: (0.1 + 0.05 × kHz)% RD + 0.1% RNG

Harmonic accuracy:

10Hz to 1kHz: 0.1% RD + 0.1% RNG

1kHz to 10kHz: (0.1 + 0.05 × kHz)% RD + 0.1% RNG

DC current accuracy: 0.1% RD + 0.1% RNG

Power

Measurement range: 75mW ~ 12kW (48 ranges)

Accuracy:

47Hz to 63Hz: 0.1% RD + 0.1% RNG

1kHz to 10kHz: (0.1 + 0.1 × kHz)% RD + 0.18% RNG

Power factor accuracy: 0.001 + (15ppm / PF) × Hz

Frequency

- Measurement range: DC, 10Hz ~ 10kHz

- Accuracy: 0.06% RD

- Reference frequency source: Voltage Source

Other

Display resolution: 5 digits

Display update rate: 0.25 sec / 0.5 sec / 1 sec / 2 sec

Power supply: 100~240V ±10%, 50/60Hz

Communication: GPIB + USB or CAN + USB

Operating temperature: 0°C ~ 40°C

Storage temperature: -40°C ~ 85°C

Safety & EMC: CE (including EMC & LVD)

Dimensions (H x W x D): 133 x 212 x 420 mm

Weight: approx. 8.5 kg

Datasheet


获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款隐私政策

快速支持

直接联系认证专家