Comet M1220 多功能记录仪-温湿度计 (AC adapter 230Vac/5Vdc)

ModelM1220
P/NM1220
联系我们
安全结算
品质保证
轻松更换与退货
支持配送

Measured value: Temperature, Relative humidity, Counted values (Dew point…)

Temperature sensor - external probe PT1000:

  Measuring range: -200 to +600 °C

  Accuracy: ±0.2 °C (-200 to +100 °C);

                   ±0.2 % from reading from +100 to +600 °C

  Resolution: 0.1 °C

Temperature + humidity sensor - external probe T+RH DIGI:

  Measuring range: according to the connected probe Digi/M

  Accuracy: according to the connected probe Digi/M

  Resolution: 0.1 °C

Dew point:

  Measuring range: according to the connected probe Digi/M

  Accuracy: according to the connected probe Digi/M

  Resolution: 0.1 °C

Temperature sensor - Thermocouple K, N:

  Measuring range: -200 to +1300 °C

  Accuracy: ± 0.3 % from the Measured value + 1.5 °C

  Resolution: 0.1 °C

Temperature sensor - Thermocouple J:

  Measuring range: -200 to +750 °C

  Accuracy: ± 0.3 % from the Measured value + 1.5 °C

  Resolution: 0.1 °C

Temperature sensor - Thermocouple S:

  Measuring range: 0 to +1700 °C

  Accuracy: ± 0.3 % from the Measured value + 1.5 °C

  Resolution: 0.1 °C

Temperature sensor - Thermocouple B:

  Measuring range: 100 to +1800 °C

  Accuracy: ± 0,3 % from the Measured value + 1 °C in the range +300 to +1800 °C

  Resolution: 0.1 °C

Temperature sensor - Thermocouple T:

  Measuring range: -200 to +400 °C

  Accuracy: ± 0.3 % from the Measured value + 1.5 °C

  Resolution: 0.1 °C

DC voltage:

  Measuring range: -60 to +140 mV; -18 to +18 mV

  Accuracy: ±100 µV; ±20 µV

  Resolution: 0.1 µV

Operating temperature: -10 to +60 °C

Channels: 4x external temperature probe

Counted values: Dew point, absolute humidity, specific humidity, mixing ratio, specific enthalpy

Memory: 1 000 000 values (noncyclic record), 600 000 values (cyclic record)

Recording interval: 1s to 24 hours

Display and alarm refresh: each 10 s

Recording mode: noncyclic - data logging stops after filling the memory

                            cyclic - after filling memory oldest data is overwritten by new

Available temperature units: degrees Celsius, degrees Fahrenheit

  Communication interface: Ethernet, USB, RS232

  Ethernet communication protocols: WWW, SNMPv1, XML, DATALINK

  Alarm protocols E-Mail

  Power: AC adapter 230Vac/5Vdc (neccessary for Ethernet interface)

  Battery life: 3 - 4 weeks

  Protection class: IP20

  Dimensions (without connectors): 178 x 95 x 37mm, without attached cables

  Weight (including batteries): approx. 380 g

Included in delivery:

  M1220

  Instruction Manual

  Traceable Calibration Certificate

  3x Rechargeable Battery AA

  Power Supply

  USB Cable

  Wall Holder

  FREE FULL VERSION Analytical Software COMET Vision

  EXTERNAL PROBES ARE NOT Included in delivery