Common problems in old sterilizers that need to be watched out for

2025年06月20日 09時08分36秒

Used autoclaves that have been operated for a long time will often encounter some unavoidable problems. So when encountering common problems with old autoclaves, what should users pay attention to and how should they handle them? EMIN invites you to learn more in the article below.

Common problems in old sterilizers after long-term use

Autoclaves are indispensable equipment in microbiology laboratories, often used to sterilize specimens and instruments at high temperatures (such as 121°C), helping to prevent contamination and ensure accurate experimental results. 

However, after a long period of operation, old autoclaves that have been used for many years often begin to develop errors, causing many inconveniences during operation. So what are these common problems?

Damaged resistor

The resistor is the main heating element in the autoclave, ensuring that the internal temperature always meets the requirements. After a long period of operation, the resistor may be corroded, covered with scale or accumulated with dust, reducing the heat generating capacity of the device.

When the resistor no longer ensures the heating function, the temperature and pressure control in the autoclave chamber may be distorted, affecting the sterilization efficiency as well as the overall operation.

Aging rubber seal

The rubber gasket surrounding the lid of the autoclave acts to prevent heat loss during the sterilization process. In equipment that has been used for many years, the rubber gasket can age and lose its elasticity, leading to heat leakage and reduced operating efficiency. Heat escaping slows down the sterilization process and poses a potential safety risk to the operator.

Lid lock is broken

In addition to the rubber gasket, the lid lock is also the part that keeps the pot lid tightly closed during operation. After many years of use, the lock on old sterilizers can be damaged, making the lid unable to close completely, thereby causing unsafe operation of the device.

Leaks at valves and pipes

Leaks in the valve or pipe of the autoclave will cause the device to not maintain the necessary tightness, directly affecting its ability to operate. Not only will the required pressure and temperature not be achieved, this problem also increases the risk of overheating and causing danger during use.

Related Posts: 

Is there any harm in using an autoclave?

How to use an autoclave and what are the uses you don't know?

Top 3 most popular autoclaves in 2023

Some things to note when operating old, long-used autoclaves

In order for autoclaves that have been used for more than 7 years to maintain good performance and provide stable sterilization results at a stable temperature, regular maintenance and inspection are essential. So what should operators pay attention to when using old equipment? 

- Regularly remove excess water remaining in the steam chamber every day and use purified water to minimize the risk of damage to the resistor. When the resistor is still good, the heat generation capacity will be stable, helping the device maintain the appropriate pressure and temperature throughout the operating cycle.

- Periodically clean the steam chamber and the pot lid every month to avoid dust accumulation, affecting the operation process. When detecting signs of rubber gasket loss or not ensuring tightness, it is necessary to replace it immediately to avoid heat loss and ensure the device always operates effectively. 

- Regularly check the tightness of the locking pins on the lid to ensure that the pot is always closed during operation. In addition, the lid closing operation must also be performed in the correct order to avoid breaking or warping the locking mechanisms.

- It is necessary to periodically monitor the temperature and pressure parameters at various points inside the autoclave using a specialized data logger with high accuracy.

- For autoclaves with integrated vacuum function, it is recommended to conduct leak testing, temperature and pressure control according to international standards such as UNI EN ISO 13060, using specialized equipment such as Tecnosoft PressureDisk Datalogger for accurate results.

相关新闻

EMIN is the Official FOTRIC Distributor in Vietnam
2026年09月25日 11時55分21秒

Since August 2020, EMIN has been an official distributor of FOTRIC products and services in Vietnam. FOTRIC specializes in thermal imaging cameras and acoustic imaging cameras for electrical inspection, industrial maintenance, leak detection, research and development, and building inspection.

EMIN is the Official JEIO TECH Distributor in Vietnam
2026年09月25日 11時13分01秒

Since September 2018, EMIN has been an official distributor of JEIO TECH products and services in Vietnam. The company specializes in developing and manufacturing laboratory equipment, environmental testing equipment, and solutions for scientific research and industrial applications.

How Is Cargo Tank Wall Thickness Inspected?
2026年09月25日 10時42分16秒

Non-destructive ultrasonic testing enables tank wall thickness measurements in areas prone to wear, corrosion, or high stress. This method helps assess the service condition of tanks used to transport hazardous materials or waste.

Selecting an Ultrasonic Coating Thickness Gauge for Wood
2026年09月25日 10時39分04秒

Ultrasonic coating thickness measurement is a non-destructive method for measuring dry coatings on wood surfaces and various wood-based materials. For total coating thickness measurements, the PosiTector 200 B1 is a suitable choice. The PosiTector 200 B3 can measure both total thickness and up to three individual coating layers, while the PosiTector 200 C3 is designed for thicker coatings.

获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款和隐私政策。

快速支持

直接联系认证专家