Core control groups on an oscilloscope and how to use them

2025年08月16日 11時27分07秒

Currently on the market there are many oscilloscope models with different configurations and features. Each model will have its own advantages, but in general they are equipped with basic controls such as horizontal axis, vertical axis, trigger, connection ports and display screens to observe waveforms.

Oscilloscope screen

On the digital Oscilloscope screen, there are always divisions, helping users to easily read and analyze signals. 

The size of each cell is not fixed but can be changed through the horizontal and vertical axis adjustment system. Normally, the vertical axis is calculated in volts/div, while the horizontal axis is calculated in time units (time/div). 

With traditional analog oscilloscopes, the screen usually only displays monochrome. Meanwhile, modern oscilloscope models are equipped with color screens, supporting faster and more accurate distinction and identification of waveforms.

Vertical axis system of oscilloscope

The vertical axis on the oscilloscope controls the voltage scale displayed on the screen. Typically, most oscilloscopes incorporate two main knobs: Volts/div and Position. 

- The Volts/div knob in the Vertical system allows you to change the voltage sensitivity, similar to zooming in or out of the waveform. Rotating clockwise will reduce the display amplitude (zoom out), while rotating counterclockwise will magnify the signal (zoom in). When the scale is small, the screen can only display low voltage signals; for detailed analysis, engineers can increase the magnification.

- The Position knob moves the waveform up or down on the display. Rotating clockwise moves the waveform down; rotating counterclockwise moves the waveform up. This is a way to “align” the entire waveform, especially useful when the signal is out of the display area.

Oscilloscope horizontal axis adjustment system

The horizontal axis on the oscilloscope is responsible for controlling the display time of the signal. Similar to the vertical axis, it is also equipped with adjustment knobs that allow you to zoom in or out of the waveform horizontally.

The horizontal axis scale is usually expressed in seconds per cell (s/div). When you turn the knob clockwise, the time period observed on the screen is expanded, allowing you to display more wave cycles at the same time. Conversely, turning it counterclockwise will “zoom in”, allowing you to observe each small part of the signal in more detail.

Refer to related articles:

The easiest guide to using an oscilloscope

What are the common functions of handheld oscilloscopes?

Why should you buy a handheld oscilloscope?

The benefits of using the KEYSIGHT EDUX1052A digital oscilloscope

Trigger system on oscilloscope

Triggers act to “fix” the waveform so that the image does not drift, so that users can observe and analyze the signal more stably. 

Some common Trigger modes include: 

- Edge Trigger: This is the most basic form, allowing the device to lock the signal based on the rising edge or falling edge of the wave. 

- Pulse Trigger: Used to capture and lock a pulse with specific characteristics of width or amplitude. For example, a pulse from 0V → 5V → 0V can be specified for precise observation.

In modern oscilloscopes, the Trigger system is increasingly diverse, supporting engineers to analyze many types of complex signals with higher stability. If you need detailed advice on oscilloscope models suitable for the lab or field, please contact EMIN for support.

相关新闻

Which products are tested using a -40°C to +150°C thermal shock chamber?
2026年07月22日 14時45分25秒

Automotive circuit boards, sensors, modules, and plastic components can all experience issues after repeated transitions between cold and hot environments. A thermal shock chamber operating from -40°C to +150°C enables the replication of these temperature fluctuations under controlled testing conditions.

Does thermal shock cause damage to electronic components?
2026年07月22日 10時40分49秒

An electronic component may operate stably under constant temperature conditions yet fail after repeated rapid transitions between hot and cold. The issue typically stems not from a specific temperature level, but rather from the rate of temperature change and the number of hot-cold cycles

The rigorous standards behind a multi-million-dollar MRI suite
2026年07月21日 14時54分01秒

An MRI system may be correctly installed and fully connected to the power supply, yet still encounter issues if the surrounding environment fails to meet technical specifications. Electromagnetic interference, RF shielding, power quality, grounding, temperature, humidity, and particulate levels are all factors that may require assessment, depending on the facility's design and the manufacturer's requirements.

Sinusoidal and Random Vibration: A Test Setup Guide for Industrial Engineers
2026年07月21日 10時30分38秒

During the operation of industrial machinery or the transportation of goods, persistent mechanical vibrations inevitably occur; these are a primary cause of material fatigue, loosened connections, and cracking in printed circuit boards (PCBs). To ensure product integrity before delivery to customers, R&D and QA/QC engineers must simulate these dynamic forces using vibration test systems.

Capacities of laboratory centrifuge tubes
2026年07月20日 13時55分40秒

Tubes with capacities of 0.2 ml, 1.5 ml, 15 ml, or 50 ml are commonly found in laboratories, yet each type is associated with specific sample categories and equipment configurations. DNA and RNA samples typically require small-volume microtubes; blood and cell samples often utilize 5 ml or 15 ml tubes; while large-volume processing workflows may require tubes of 50 ml, 100 ml, or greater capacity

获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款隐私政策

快速支持

直接联系认证专家