Measuring Mode:
Single Echo with Twin Crystal Probes
Echo-Echo with Twin Crystal Probes
Multiple Echo with Singly Crystal Probes
Materials: Sound velocity from 1000 m/s to 9000 m/s [0.0390 in/us to 0.3543 in/us]
Accuracy: ±0.1 mm (±0.004”) or 0.1% of thickness measurement whichever is the greatest
Resolution: 0.1mm, 0.05mm or 0.01mm depending on probe type
Probe Options: Single crystal and twin crystal probes
Measurement Range in Steel: 0.8mm to 250mm (0.031 in. – 10 in.) depending on selected probe and configuration, material and temperature
Connector: Single Dual Coaxial Connector
Power Supply: Rechargeable, removable Lithium-Ion battery pack
Power Rating: 2W
Probe Sockets: Single Dual Coaxial Connector
Battery Life: 6-8 hours continuous measurement
Display: 3.5” VGA, sunlight readable colour display
Size: 270mm tall, 135mm wide, 80mm deep
Weight: 1 kg with battery
Operating Temp: -0°C to +50°C (32°F to 122°F)
Storage Temp: -10°C to +65°C (50°F to 149°F)
Data Logging: 10,000 measurements and A-scans per record
Computer Software: CygLink allows remote logging and viewing of A-scan graphs. Survey and report generation to PDF file. Graphic analysis of data and statistical calculations. Bluetooth connection to transfer data to a Windows® computer with CygLink