直接联系认证专家

Electrostatic Fieldmeter
Input voltage: +24VDC (±10%)
Current consumption: <150mA
Sensor: Oscillating chopper type (DIT)
Sensing distance: Precise mode: 25mm (±0.5mm); Expanded mode: 50–500mm (±0.5mm), interval: 1m
Range: Precise mode: ±2kV (±5%); Expanded mode: ±20kV (±10%)
Resolution: Precise mode: 1V; Expanded mode: 10V
Accuracy:
Precise mode: ±2kV (±5%)
Expanded mode: 50–300mm: ±20kV (±10%); 301–500mm: ±20kV (±20%)
Linearity: ±5% F.S
Response time: 200ms (Can be programmed)
Analog output: ARM-S050W1 (1–5V); ARM-S050U1 (0–5V); ARM-S050C1 (4–20mA)
Communication: RS-485 Wire (30m) communication
Display: 4-DIGIT FND
Case: ABS
Ambient temperature: 0℃ ~ 50℃
Ambient humidity: 35–85% RH (No condensation)
Ultrasonic Sensor
Input voltage: +24VDC (±10%)
Sensor: Reflex type
Sensing distance: 50–500mm (Target: 100×100 plate)
Resolution: 0.5mm
Analog output: None
Case: Glass + Epoxy