直接联系认证专家
Measurement Mode: PE, PETP, EE, EEV, CT, PECT
Measurement Rate:
+ 4 readings per second
+ 50 readings per second
+ 6 readings per second
Measuring Range
+ PE: 0.63 - 508mm
+ PETP: 0.63 - 508mm
+ EEV: 1.27 - 25.4mm
+ PECT: 0.63 - 508mm
+ PECT: 0.01 - 2.54mm
Calibration Options: Single, two point, velocity & material type
Measurement Accuracy: ± 1% or ±0.1mm
Measurement Resolution: 0.01 mm
Velocity Calibration Range: 1250 - 9,999m/s
B-Scan display speed: 15 seconds per screen
Transducer Frequency Range: 1 - 10MHz
Display: 1/8 inch VGA, Display Refresh Rate 25Hz
Battery Type: 3 x AA alkaline
Battery Life: 150 hours
Operating Temperature: -10 to 60ºC
Size (w x h x d): 63.5 x 165.0 x 31.5mm
Weight (including batteries): 383g
RS232 Interface: Bi-directional
Packing List: Elcometer NDT CG100B gauge, couplant, carry case, user manual, test certificate, 3 x AA batteries
Note: A transducer is not suppied with the Gauges, must be ordered separately
The Elcometer CG100 ultrasonic corrosion thickness gauge is available in four models - from an entry level CG100B to the top of the range CG100ABDL+.
![]() |
Features:
|
|
Model & Part Number |
CG100B |
CG100BDL |
CG100ABDL |
CG100ABDL+ |
|
Material thickness digits display |
■ |
■ |
■ |
■ |
|
B-Scan cross sectional display |
■ |
■ |
■ |
■ |
|
Combined B-Scan and digits display |
■ |
■ |
■ |
■ |
|
Scan bar display |
■ |
■ |
■ |
■ |
|
Coating thickness display |
■ |
■ |
■ |
■ |
|
A-Scan Display |
|
|
+ Rectified, - Rectified, |
+ Rectified, - Rectified, |
|
Measurement Mode |
PE, PETP (Temp Compensation), |
PE, PETP (Temp Compensation), |
PE, PETP (Temp Compensation), |
PE, PETP (Temp Compensation), |
|
Measurement Rate |
4 readings per second |
4 readings per second |
4 readings per second |
4 readings per second |
|
Measuring Range |
PE: 0.63 - 508mm |
PE: 0.63 - 508mm |
PE: 0.63 - 508mm |
PE: 0.63 - 508mm |
|
Measurement Accuracy |
± 1% or ±0.1mm |
± 1% or ±0.1mm |
± 1% or ±0.1mm |
± 1% or ±0.1mm |
|
Measurement Resolution |
0.01mm (0.001 inches) |
0.01mm (0.001 inches) |
0.01mm (0.001 inches) |
0.01mm (0.001 inches) |
|
Velocity Calibration Range |
1250 - 13,995m/s |
1250 - 13,995m/s |
1250 - 13,995m/s |
1250 - 13,995m/s |
|
Additional Features: |
■ |
■ |
■ |
■ |
|
Differential mode |
■ |
■ |
■ |
■ |
|
Limit alarm mode |
■ |
■ |
■ |
■ |
|
B-Scan display speed |
15 seconds per screen |
15 seconds per screen |
Adjustable display speed |
Adjustable display speed |
|
Flaw mode |
|
|
Basic prove-up flaw detection using single element angle beam transducers |
Basic prove-up flaw detection using single element angle beam transducers |
|
Calibration setups |
6 factory & 64 user-definable setups transferrable to and from a PC archive |
6 factory & 64 user-definable setups transferrable to and from a PC archive |
6 factory & 64 user-definable setups transferrable to and from a PC archive |
6 factory & 64 user-definable setups transferrable to and from a PC archive |
|
Gates |
|
|
3 fully adjustable gates: start, stop, width & threshold |
3 fully adjustable gates: start, stop, width & threshold |
|
Damping |
|
|
|
Adjustable; impedance matching for optimising transducer performance |
|
Pulser type |
Dual square wave pulsers up to 140Hz pulse repetition rate |
Dual square wave pulsers up to 140Hz pulse repetition rate |
Dual 200 volt square wave pulsers with adjustable pulse width(spike, thin, wide) and 50 volt cut/boost for greater penetration |
Dual 200 volt square wave pulsers with adjustable pulse width |
|
Gain |
Automatic gain control (AGC) with 110dB range (limited), or selectable gain: vlow, low, medium hi or vhi |
Automatic gain control (AGC) with 110dB range (limited), or selectable gain: vlow, low, medium hi or vhi |
Manual, automatic gain control (AGC) with 110dB range (limited) |
Manual, automatic gain control (AGC) with 110dB range (limited) |
|
Timing |
Precision 25MHz TCXO with single shot 100MHz 8bit ultra low power 8 bit digitizer |
Precision 25MHz TCXO with single shot 100MHz 8bit ultra low power 8 bit digitizer |
Precision 25MHz TCXO with single shot 100MHz 8bit ultra low power 8 bit digitizer |
Precision 25MHz TCXO with single shot 100MHz 8bit ultra low power 8 bit digitizer |
|
Data logging |
|
|
|
|
|
Calibration Options |
Single, two point, velocity & material type |
Single, two point, velocity & material type |
Single, two point, velocity & material type |
Single, two point, velocity & material type |
|
Transducer Probe Type |
Dual element |
Dual element |
Dual element & flaw prove up |
Dual element & flaw prove up |
|
Transducer Frequency Range |
1 - 10MHz |
1 - 10MHz |
1 - 10MHz |
1 - 10MHz |
|
Transducer recognition |
Automatic & manual - selectable from a list |
Automatic & manual - selectable from a list |
Automatic & manual - selectable from a list |
Automatic & manual - selectable from a list |
|
V-path / dual path error correction |
Automatic |
Automatic |
Automatic |
Automatic |
|
Probe zero |
Automatic & manual (via integrated probe disk) |
Automatic & manual (via integrated probe disk) |
Automatic & manual (via integrated probe disk) |
Automatic & manual (via integrated probe disk) |
|
Display |
1/8 VGA (grayscale) |
1/8 VGA (grayscale) |
1/8 VGA (grayscale) |
1/4 VGA AMOLED colour display |
|
Display Refresh Rate |
25Hz |
25Hz |
25Hz |
120Hz |
|
Units (selectable) |
mm or inches |
mm or inches |
mm or inches |
mm or inches |
|
Backlight |
on / off / auto |
on / off / auto |
on / off / auto |
adjustable brightness |
|
Repeatability / Stability Indicator |
■ |
■ |
■ |
■ |
|
Battery Type |
3 x AA alkaline |
3 x AA alkaline |
3 x AA alkaline |
3 x AA alkaline |
|
Battery Life (approximate) |
150 hours |
150 hours |
50 hours |
25 hours |
|
Low Battery Indicator |
■ |
■ |
■ |
■ |
|
Battery Save Mode |
auto |
auto |
auto |
auto |
|
Operating Temperature |
-10 to 60ºC (14 to 140ºF) |
-10 to 60ºC (14 to 140ºF) |
-10 to 60ºC (14 to 140ºF) |
-10 to 60ºC (14 to 140ºF) |
|
Size (w x h x d) |
<td style="border:solid windowtext 1.0pt;mso-border-alt:solid windowtext .5pt;