Fluke Network DSX2-5000-NW AP Cable Analyzer (1GHZ, Non-wireless)
Cable Types
Shielded and unshielded pair LAN cabling: TIA Category 3, 4, 5, 5e, 6, 6A, 8: 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω
Standard Link Interface Adapters
Permanent link adapters
Plug type: shielded RJ45
Optional Plug type: Tera
Channel Adapters
Jack type: shielded RJ45
Optional Jack type: Tera, GG45
Test Standards
TIA: Category 3, 4, 5, 5e, 6, 6A, 8 per ANSI/TIA-568.2-D
ISO/IEC: Class C and D, E, EA, F, FA and I/II certification per ISO/IEC
Maximum frequency: 1000 MHz
General Specifications
Speed of Autotest: Full 2-way Autotest of Category 5e or 6/Class D or E: 9 seconds. Full 2-way Autotest of Category 6A/Class EA: 10 seconds
Input protection: Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display: 5.7 in LCD display with a projected capacitance touchscreen
Case: High impact plastic with shock absorbing overmold
Dimensions: Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight: Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote: Lithium ion battery pack, 7.2 V
Typical battery life:8 hours
Charge time*
Tester off: 4 hours to charge from 10 % capacity to 90 % capacity.
Languages supported: English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
Calibration: Service center calibration period is 1 year
Delay Skew
Range: 0 ns to 100 ns
Resolution: 1 ns
Accuracy: ± 10 ns
DC Loop Resistance Test
Range: 0 Ω to 540 Ω
Resolution: 0.1 Ω
Accuracy: ± (1 Ω + 1 %)
Overload recovery time
Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage.