Capacity, m3/hour, minimum/gals. per hour:
• drying, regeneration and filtration mode: 1.5-2.0/392-529
• heating mode: 3.6-4.3/953-1138
Max oil outlet temperature, ⁰С/⁰F:
• drying and filtration mode: 35/95
• heating mode: 65/149
Sorbent max load, kg: 100
Sorbent regeneration temperature, ⁰С/⁰F:
Zeolite NaA: 250/482
Silica gel: 120/248
Sorbent regeneration without unloading: Yes
Processed oil parameters:
• industrial purity class (ISO 4406): 9 (-/14/12)
• solid particle content, max, g/t: 10
• acid number, mg KOH/g of oil, max: 0.02…0.05
• nominal filtration fineness, micron: 5
• mass weight content, g/ton per cycle, max: 10
• dielectric loss tangent at 90 ⁰С/194 ⁰F, max: 1.5
• dielectric strength, kW, min: 65
Mean heater surface power, W/cm2, max: 1.2
Heater power, kW, max: 28.8
Max power consumption, kW: 33
Three phase AC power voltage, 50/60Hz, V: 380
Dimensions, mm/ft, max, length/width/height: 1500/900/1735 (4’59”/2’95”/5’69”)
Weight, kg/lbs, max: 750/1,657.5