直接联系认证专家

Accuracy:
Cx ±(reading×1%+1pF)
PF ±(reading×1%+0.00040)
Anti-Interference:
Variable frequency anti-interference, it can still achieve the above accuracy under 200%
Interference
Capacitance Range:
Internal HV: 3pF~60000pF / 10kV, 60pF~1µF / 0.5kV
External HV: 3pF~1.2µF / 10kV, 60pF~30µF / 0.5kV
Resolution: 0.001pF, 4 digits
tgδ Range: No limit, Resolution 0.001%, C/L/R automatic recognition
Test mode: UST, GST, GST-g, CVT self-excitation
Input current range: 10μA~5A
Internal HV:
Voltage range:0.5~10kV
Current: 200mA (max)
Voltage up/down: continuous smooth adjustment
Voltage accuracy: ± (1.5% × reading + 10V)
Voltage resolution: 1V
Test frequency:
45~65Hz integer Frequency
45/55Hz, 49/51Hz automatic dual variable frequency
Frequency accuracy: ±0.01Hz
External HV:
UST: max test current: 1A (40-70Hz)
GST: max test current 10kV/1A (40-70Hz)
CVT self-excitation: Output voltage:3 ~ 50V, output current:3 ~ 30A
HV Accuracy: ±(1.5% x reading×1%+10V), Resolution: 1V
Test Time: Approx 30S, It is related to measurement mode
PC connection: RS232 (for optional)
Power Supply: 180V~270V 50Hz/60Hz, mains or generator power supply
Operating Temperature: -10℃~50℃
Humidity: <90%, no condensation
Dimesion: 470×350×355mm
Net Weight: 28kgs
Accessories
Host: 1 unit
HV cable (8m): 1 unit
LV cable (6m): 2 units
Power line: 1 unit
Earth line (5m): 1 unit
CVT wire: 2 units
5A fuse: 2 units
Operating Manual: 1 unit
Calibration: 1 unit