Proper calibration of self-recording thermometers and hygrometers.

2026年01月06日 10時46分58秒

A self-recording hygrometer is a device used to monitor the temperature and humidity of the air. The device can automatically record data over time, allowing users to easily understand changes in the surrounding environment. The information is displayed visually on the screen, making observation and management of spatial conditions easier and more convenient.

What is calibration for a data logging thermometer/hygrometer?

Simply put, calibration is the process of bringing a hygrometer back to a state that accurately measures real-world values. After prolonged use, the sensor is easily affected by the environment, high humidity, constantly changing temperatures, or component degradation. In such cases, the data may still be displayed, but the deviation may gradually increase, making it difficult for users to accurately assess air conditions.

Typically, this process is performed at testing or warranty centers, where standard equipment is available for comparison and adjustment. This method helps keep the error within acceptable limits and ensures the device maintains stable operation.

Users can perform the operation themselves if they have technical knowledge and the necessary tools. However, incorrect operation can easily misalign the sensor, even causing damage or risks during use. For equipment used in storage, laboratories, or for long-term monitoring, choosing a professional service provider is still a safer option.

Why is calibration necessary for data logging thermometers and hygrometers?

After a period of use, self-recording hygrometers are inevitably prone to measurement inaccuracies or minor sensor errors. Environmental changes, high humidity, constantly fluctuating temperatures, or simply component degradation can all cause measurement results to no longer accurately reflect reality. Continued use in this state will result in less valuable and less reliable data for monitoring purposes.

Typically, a calibration cycle is recommended around every six months. This timeframe allows for a comprehensive check of the device's functionality and adjustment of parameters to ensure more stable temperature and humidity measurements. This helps maintain the necessary accuracy over long-term use.

See also: Humidity-Temperature Data Logger

Calibration procedure for self-recording hygrometers

1. External Inspection

The first step is to observe the device as a whole. Compare the size, appearance, display screen, and power supply with the information on the manufacturer's label. This inspection helps to detect early display errors, power supply errors, or basic malfunctions that may affect subsequent measurement results.

2. Measuring and Calibrating Humidity

Common humidity levels for testing include 30% RH, 60% RH, and 90% RH, depending on actual usage requirements. Place the self-recording hygrometer and standard probe together in a humidity chamber. After the environment stabilizes, compare the data and determine the difference. If the error exceeds the permissible limit, the technician will readjust the equipment according to the agreed-upon requirements. A calibration certificate will be issued upon completion of this process.

3. Temperature Measurement and Calibration

The commonly selected temperature levels are 15°C, 25°C, and 35°C, or according to specific application conditions. The equipment to be calibrated and the reference probe are placed in the temperature-generating chamber. The chamber is adjusted sequentially to each mark, and then the measurement results are compared to identify any discrepancies. If necessary, the parameters are fine-tuned to bring the equipment to a stable measurement state.

4. Recommendations

Regular calibration is recommended to ensure the reliability of recorded data. In cases of significant errors or unstable operation, calibration may be performed earlier than scheduled.

Notes on calibrating a self-recording thermometer/hygrometer.

The ideal environment for this experiment is between 18 and 28 degrees Celsius, with humidity ranging from 20% to 80%. Before starting, it is necessary to prepare the heating and humidifying chamber, reference equipment, and humidification chamber to ensure a smooth process and accurate results.

相关新闻

Guide to Selecting Case and Sensor Materials for Pressure Gauges in Corrosive Chemical Environments
2026年10月13日 11時14分57秒

In chemical processing plants, wastewater treatment facilities, oil & gas operations, and food production, selecting the wrong material for a pressure gauge often leads to severe consequences: Bourdon tube failure, toxic chemical leaks, equipment breakdown, and serious occupational safety hazards. This article provides practical technical criteria for selecting the correct case and sensor materials when measuring pressure in corrosive environments.

Measuring COD and TOC in Electroplating Wastewater Using a Benchtop Analyzer? What Sources of Error Should Be Avoided?
2026年10月13日 10時55分11秒

The current situation regarding electroplating wastewater analysis presents challenges: the wastewater contains acids, alkalis, and heavy metals (such as Cr, Ni, and Cu), alongside persistent cyclic organic compounds derived from brightening agents, anti-misting additives, and degreasing solvents. This complex composition causes significant fluctuations in COD levels depending on the specific process stage and production shift. Sending samples to external laboratories results in a delay of several days—by which time the biological treatment tanks or coagulation systems may have already been operating improperly for too long. Utilizing a benchtop COD analyzer on-site reduces this turnaround time to just a few hours, provided the user fully understands the specific sources of error associated with electroplating wastewater

How to Rapidly Reduce COD in Domestic Wastewater?
2026年10月13日 10時25分11秒

Wastewater treatment plants serving apartment complexes, buildings, and residential areas sometimes experience effluent COD levels approaching regulatory limits, particularly following sudden load surges or shortly before scheduled compliance sampling. QCVN 14:2025/BTNMT, applicable to domestic wastewater from September 1, 2025, sets COD limits based on discharge volume and the receiving water body, while allowing dischargers to choose between TOC and COD parameters

Challenges of Pressure Gauges in Hydrogen Environments
2026年10月12日 16時47分15秒

The global energy transition trend is driving industrial plants, chemical facilities, and renewable energy sites to integrate hydrogen as a strategic fuel source to achieve decarbonization goals. However, practical experience shows that traditional mechanical pressure gauges rapidly degrade in service life and experience dangerous failures when in direct contact with hydrogen environments.

The Trend of Eliminating Mechanical Pressure Gauges in Semiconductor Fabrication Plants
2026年10月12日 14時44分38秒

In semiconductor cleanrooms, a single microscopic dust particle or a tiny toxic gas leak is enough to ruin an entire wafer batch worth millions of dollars. This vital requirement is accelerating a complete transition from traditional mechanical pressure gauges to digital pressure sensors and electronic pressure gauges.

获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款和隐私政策。

快速支持

直接联系认证专家