Specification
- Resistance range:
   + 100 mΩ(Max.120mΩ, 0.1μΩ resolution)) to 100MΩ(Max.120MΩ, 100Ω resolution), 10 steps
   + 1000mΩ(Max.1200mΩ, 1μΩ resolution) to 1000Ω(Max.1200Ω, 1mΩ resolution), 4 steps
- Display:Monochrome graphic LCD 240 × 64 dot, white LED backlight
- Measurement accuracy:
   + 100mΩ ±0.015 % rdg. ±0.002 % f.s.
   + 1000 Ω ±0.006 % rdg. ±0.001 % f.s
- Testing current:
   + 100mΩ range: 100mA DC
   + 100MΩ range: 100 nA DC
- Open-terminal voltage:     20 V DC max.
- Sampling rate: FAST, MEDIUM, SLOW, 3 settings
- Measurement times:
   + 100 Ω /1000 Ω ranges: FAST: 0.9 ms, MED: 3.6 ms, SLOW: 17 ms (minimum time)
- Integration time: 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz
- Other functions:     Comparator , Delay, OVC (offset voltage compensation), Measurement fault detection, Probe short-circuit detection, Improve contact, Auto-memory, Statistical calculations, Settings monitor , Trigger function
- Interface: RS-232C, Printer, GP-IB (Model RM3542-01)
- External I/O:    Trigger, Hold input, Comparator output, Settings monitor terminal
- Power supply, consumption: 100 to 240 V AC, 50/60 Hz, 30 VA max.
- Dimensions, mass:    260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 2.9 kg (102.3 oz)
- Supplied accessories:    Power cord × 1, EXT I/O male connector × 1, Operation manual × 1, Operation guide × 1
- The warrnty preiod: 12 month

Resistance range [at Low Power OFF] 100 mΩ range (Max. 120.0000 mΩ, 0.1μΩ resolution)) to 100 MΩ range (Max. 120.0000 MΩ, 100 Ω resolution), 10 steps
[at Low Power ON] 1000 mΩ range (Max. 1200.000 mΩ, 1 μΩ resolution) to 1000 Ω range (Max. 1200.000 Ω, 1 mΩ resolution), 4 steps
Display Monochrome graphic LCD 240 × 64 dot, white LED backlight
Measurement accuracy [with SLOW mode, at 100 mΩ range] ±0.015 % rdg. ±0.002 % f.s.
[with SLOW mode, at 1000 Ω range] ±0.006 % rdg. ±0.001 % f.s. (the best case)
Testing current [at 100 mΩ range] 100 mA DC to [at 100 MΩ range] 100 nA DC
Open-terminal voltage 20 V DC max.
Sampling rate FAST, MEDIUM, SLOW, 3 settings
Measurement times [at 100 Ω /1000 Ω ranges, with Low Power OFF] FAST: 0.9 ms, MED: 3.6 ms, SLOW: 17 ms (minimum time)
Integration time 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz
Note: PLC = one power line cycle (mains wave-form period)
Other functions Comparator (compare setting value with measurement value), Delay (set to allow for mechanical delay of trigger input and probing, or set to allow for measurement object response), OVC (offset voltage compensation), Measurement fault detection, Probe short-circuit detection, Improve contact, Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,.
Interface RS-232C, Printer, GP-IB (Model RM3542-01)
External I/O Trigger, Hold input, Comparator output, Settings monitor terminal
Power supply, consumption 100 to 240 V AC, 50/60 Hz, 30 VA max.
Dimensions, mass 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 2.9 kg (102.3 oz)
Supplied accessories Power cord × 1, EXT I/O male connector × 1, Operation manual × 1, Operation guide × 1