Specification
-Measurement methods: Measurement of voltage drop across body simulated resistance points
Calculation and display of current values True rms measurement
Measurement unit floats relative to instrument ground.
- Measurement modes: Leak current measurement, voltage measurement, safety conductor current measurement
- Standard compliance:
  + IEC  IEC 60990 (1999) 
  + IEC 61010-1 (2001)
  + UL-1492 (1996)
  + IEC 60335-1 (2001) + A1:2004 + A2:2006
  + IEC 60065 (2001) + A1:2005
  + UL-2231-1 (2002), UL-2231-2 (2002)
- Leak current measurement:      Ground leak current, 3 types of contact current, 7 types of patient leak current, patient measurement current, 4 types of total patient leak current, free current measurement, 3 types of enclosure leak current
- Measurement current: DC, AC (15 Hz to 1 MHz), AC+DC (15 Hz to 1 MHz), AC peak (15 Hz to 1 MHz)
- Measurement ranges:      DC / AC / AC+DC mode:50 μA/500 μA/5 mA/50 mA
AC peak mode:500 μA/1 mA/10 mA/75 mA
- Measurement accuracy: DC measurement: ±2.0% rdg. ±6 dgt. (typ.)
AC / AC+DC measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 100 kHz, typ.)
AC peak measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 10 kHz, typ.)
- Interfaces: External I/O, medical device relay output, USB 1.1 (communications), RS-232C
- Functionality: 110% voltage application, automatic test, data storage for 100 target devices, clock, data backup, printed output (optional), etc.
- HiTESTER power supply: 100/120/220/240 V AC (specify at time of order), 50/60 Hz, 30 VA rated power
- Target device power supply input: 100 to 240 V AC, 50/60 Hz Rated current input from terminal block: 20 A
- Dimensions, mass: 320 mm (12.60 in) W × 110 mm (4.33 in) H × 253 mm (9.96 in) D, 4.5 kg
- Supplied accessories: TEST LEAD L2200 (for ST5540, Red ×2, Black ×1) ×1 set, ENCLOSURE PROBE 9195 ×1, Power cord ×3, Spare fuse for measurement line ×1, Instruction manual ×1, Users guide ×1, CD-ROM ×1
-  The warranty period: 12 month
 

Measurement methods Measurement of voltage drop across body simulated resistance points
Calculation and display of current values True rms measurement
Measurement unit floats relative to instrument ground.
Measurement modes Leak current measurement, voltage measurement, safety conductor current measurement
Standard compliance Electrical Appliances and Materials Safety Act
Measurement of touch current and protective conductor current: IEC 60990 (1999)
Electrical equipment for measurement, control, and laboratory use: IEC 61010-1 (2001)
Information technology equipment: IEC 60950-1 (2005)
Household and similar appliances: IEC 60335-1 (2001) + A1:2004 + A2:2006
Audio, video and similar electronic apparatus: IEC 60065 (2001) + A1:2005
Personnel Protection Systems for EV: UL-2231-1 (2002), UL-2231-2 (2002)
UL: UL-1492 (1996)
Electrical equipment for measurement, control, and laboratory use; current measurement circuits in damp conditions: IEC 61010-1 (2001)
Leak current measurement Ground leak current, 3 types of contact current, free current measurement, 3 types of enclosure leak current
Measurement current DC, AC (true rms, 15 Hz to 1 MHz), AC+DC (true rms, 15 Hz to 1 MHz), AC peak (15 Hz to 1 MHz)
Measurement ranges DC / AC / AC+DC mode:50 μA/500 μA/5 mA/50 mA
AC peak mode:500 μA/1 mA/10 mA/75 mA
Measurement accuracy
(current measurement)
DC measurement: ±2.0% rdg. ±6 dgt. (typ.)
AC / AC+DC measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 100 kHz, typ.)
AC peak measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 10 kHz, typ.)
Interfaces External I/O, USB 1.1 (communications), RS-232C
Functionality Automatic test, data storage for 100 target devices, clock, data backup, printed output (optional), etc.
HiTESTER power supply 100/120/220/240 V AC (specify at time of order), 50/60 Hz, 30 VA rated power
Target device power supply input 100 to 240 V AC, 50/60 Hz Rated current input from terminal block: 20 A
Target device power supply output Output from terminal block: 20 A Output from outlet: 15 A
Dimensions, mass 320 mm (12.60 in) W × 110 mm (4.33 in) H × 253 mm (9.96 in) D, 4.5 kg (158.7 oz)
Supplied accessories TEST LEAD L2200 (Red ×1, Black ×1) ×1 set, ENCLOSURE PROBE 9195 ×1, Power cord ×3, Spare fuse for measurement line ×1, Instruction manual ×1, Users guide ×1, CD-ROM ×1