For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

HT Instruments PV-215 直流综合性能测试仪

ModelPV-215
原产地Italy
保修1 年
联系我们
安全结算
品质保证
轻松更换与退货
支持配送

1. PERFORMANCE TEST

DC Voltage: 5.0 ÷ 999.9; ± (1.0%rdg + 2dgt) 

DC current (by mean external clamp) : 

-1100 ÷ -5/ 5 ÷ 1100; ± (0.5%rdg + 0.6mV)

1< FS ≤ 10: 0.001; 0.05 

10< FS ≤ 100: 0.01; 0.5  

100< FS ≤ 1000: 0.1; 5 

DC Power (Vmeas > 150V): 

1< FS ≤ 10: 0.000k ÷ 9.999k; ±(1.5%rdg + 3dgt)(Imeas < 10%FS); ±(1.5%rdg)(Imeas ≥ 10%FS)

10< FS ≤ 100: 0.00k ÷ 99.99k; ±(1.5%rdg + 3dgt)(Imeas < 10%FS); ±(1.5%rdg)(Imeas ≥ 10%FS)

100< FS ≤ 1000:0.0k ÷ 999.9k ; ±(1.5%rdg + 3dgt)(Imeas < 10%FS); ±(1.5%rdg)(Imeas ≥ 10%FS)

Irradiance (by mean HT304N): 1 ÷ 40.0; ±(1.0%rdg + 0.1mV) 

Temperature (by mean PT300N): -20.0 ÷ 100.0; ± (1.0%rdg +1°C) 

2. FUNCTIONALITY TE

DC Voltage @ OPC: 5.0 ÷ 999.9; ± (1.0%rdg + 2dgt) 

DC Current @ OPC: 0.10 ÷ 15.00; ± (1.0%rdg + 2dgt) 

DC Voltage @ STC: 5.0 ÷ 999.9; ± (4.0%rdg + 2dgt) 

DC Current @ STC: 0.10 ÷ 15.00; ± (4.0%rdg + 2dgt)

Irradiance (by mean HT304N): 1 ÷ 40.0; ±(1.0%rdg + 0.1mV) 

Temperature (by mean PT300N): -20.0 ÷ 100.0; ±(1.0%rdg +1°C) 

3. SAFETY TEST 

Continuity Test (LOWΩ):  0.00÷ 199; ±(2.0%rdg + 2dgt) 

Insulation Test (MΩ) – Mode TIMER:  250, 500, 1000; 0.01 ÷ 199; ±(5.0%rdg+ 5dgt) 

Insulation Test (MΩ) – Mode FIELD (*), STRING (**):  250, 500, 1000; 0.1 ÷ 99; ±(20.0%rdg+ 5dgt)  


Accessories provided

User manual and quick guide

ISO9000 calibration certificate

Standard Clamp HT4004

Bag BORSA2051

Set of Adapter KITPCMC4

Set of Adapter KITPCMC3

Set of Cabled and Alligator Clips KITGSC4

Multi- Language Software TOPVIEW2006


Manual 


Datasheet 