直接联系认证专家
Input Characteristics:
Voltage: 220VAC, ±10%, single phase, Optional
Frequency: 47-63Hz
Fuse: 4A/250VAC
AC Withstand Voltage Test:
Rated Output: 5KV AC
Output Frequency: 50 or 60Hz, optional
Output Waveform: Sine wave, 1.3 < Crest Factor < 1.5
Leakage Current - High Limit:
Range: 0.01-20.00mA
Resolution: 0.01mA
Accuracy: ±(2% set value + 2 characters)
Leakage Current - Low Limit:
Range: 0.00-20.00mA
Resolution: 0.01mA
Accuracy: ±(2% set value + 2 characters)
DC Withstand Voltage Test:
Rated Output: 6KV DC
Leakage Current - High Limit Setting:
Range: 0.01-10.00mA
Resolution: 0.01mA
Accuracy: ±(2% set value + 2 characters)
Leakage Current - Low Limit Setting:
Range: 0.00-10.00mA
Resolution: 0.01mA
Accuracy: ±(2% set value + 2 characters)
Voltage Setting:
Range: 0-5000V AC, 0-6000V DC
Resolution: 1V
Accuracy: ±(2% set value + 5V)
Voltage Stability: ±(1% set value + 5V)
Ramp Time:
Range: 0.1-999.9S
Resolution: 0.1S
Accuracy: ±(0.1% set value + 0.05S)
Test Time:
Range: 0.5-999.9S, 0 is continuous test
Resolution: 0.1S
Accuracy: ±(0.1% set value + 0.05S)
Voltage Display:
Range: 0-5.00KV AC, 0-6.00KV DC
Resolution: 0.01KV
Accuracy: ±(3% set value + 3 characters)
Current Display:
Range: 0.01-20.00mA AC, 0.01-10.00mA DC
Resolution: 0.01mA
Accuracy: ±(2% set value + 3 characters)
Insulation Resistance Test:
Rated Output: 1000V DC
Voltage Setting Range:
Range: 500-1000V DC
Resolution: 1V
Accuracy: ±(2% set value + 5V)
Voltage Display:
Range: 0.50KV – 1.00KV DC
Resolution: 0.01KV
Accuracy: ±(2% set value)
Resistance Display:
Range: 1.000-2000MΩ
Accuracy: ±(5% set value + 3 characters) (1-1000MΩ), ±(10% set value + 3 characters) (1000-2000MΩ)
Resistance High Limit Setting: 0-2000MΩ, 0 is not judged
Resistance Low Limit Setting: 1.0-999.9MΩ
Judge Delay Time:
Range: 0.8-999.9S, 0 is continuous judgment
Resolution: 0.1S
Accuracy: ±(0.1% set value + 0.05S)
Ground Resistance Test:
Voltage Output: <7VAC
Peak Current Display: 3.0-30.0A, ±(3% display value + 3 characters)
Ground Resistance:
Upper Limit Setting:
1-300mΩ (3-10A)
1-120mΩ (11-30A)
Resistance Display: 0-300mΩ
Test Time: 0.5-999.9S, 0 is continuous
Datasheet
Manual
Product Description:AC/DC withstand voltage/ Insulation/ Grounding resistance tester
l Suitable for photovoltaic products, household appliances, medical equipment, audio-visual equipment, IT equipment, television equipment, transformers and motor transformers
l Voltage and insulation ground automatic conversion test mode
l The voltage is increased by the time gradient
l Set current and resistance limit
l With arc detection function (1-9 level)
l 3 groups of test memory patterns
l Optional RS232C interface and PLC interface