For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

KEYSIGHT RP7984A Regenerative Power System (1500 V, ±60 A, 30 kW)

联系我们
安全结算
品质保证
轻松更换与退货
支持配送

DC Ratings: 

Voltage source: 0 to 1500 V

Current source and sink :  0 to ± 60 A

Power : 0 to ± 30 kW

Output ripple and noise: 

CV peak-to-peak (1) : 2.25 V

CV rms (2) :  300 mV

Load regulation: 

Voltage (3) : 75 mV

Current 24mA 12 mA 4 mA 8 mA: 

Voltage programming and measurement accuracy (4): 0.03% + 100 mV

Current programming and measurement accuracy (4): 0.03% + 6 mA

Transient response (5): 

Recovery Time : 300 μs

Settling band : 15 V

(1). From 20 Hz to 20 MHz (-3 dB bandwidth) with resistive load, terminals ungrounded, or either terminal grounded.

(2). From 20 Hz to 10 MHz (-3 dB bandwidth) with resistive load, terminals ungrounded, or either terminal grounded.

(3). Also applies when remote sensing with a ≤ 1 V drop per load lead.

(4). Percent of value + offset; at 25 °C ± 5 °C after a 30-minute warm-up; measurement NPLC=1; valid for 1 year.

(5). Time to recover to within the settling band following a step change from 40% to 90% and 90% to 40% of full load at Comp 0 with a 40 μs current rise and fall time.