Reliability Test for Relay Using GW PSW Power Supply and PEL-3111 E. Load

2017年12月19日 17時28分24秒

How do you conduct relay connection point (N.O. / N.C.) tests? How do you test the life cycle of relay’s connection point (N.O. / N.C.)?   How do you evalua

How do you conduct relay connection point (N.O. / N.C.) tests? How do you test the life cycle of relay’s connection
point (N.O. / N.C.)?   How do you evaluate the connection resistance of connection point (N.O. / N.C.) after multiple
tests? How do you evaluate the speed for operating connection point (N.O. / N.C.)? 

Relay, functioning to produce mechanical on-off movement by receiving electric signal to change electro magnet,
is often applied to control other electronic device via receiving electronic signal. Voltage exerted on relay’s coil
allows current to pass through coil and magnetizes core. Armature is then be pulled by core due to electromagnetic
force. Hence, a mechanical on-off movement is produced.  


As shown on the top diagram, PSW 30-108, Relay and PEL-3111 are connected by series. PEL-3111 is set to 80A
current sink. Each time, Relay’s NO-COM is closed, NO-COM is tested for its current reliability. In the meantime,
PSW 80-40.5 is utilized to output sequential power supply to produce control signal to control Relay’s NO-COM.

One GW Instek PSW 80-40.5 can meet the actual measurement requirements via planning Relay’s control signal.
It not only controls signal’s voltage, current, time and period, but also determines the number of operating cycle.
There are totally 20,000 steps and each step can be set from 50ms to 20 days. The number of cycle can reach
1 billion or infinite by different specifications. Relay’s control signal can only verify the mechanical characteristics
of NO-COM and NC-COM. For further electric characteristic verification of NO-COM and NC-COM, PSW 30-108
and PEL-3111 must be concurrently utilized to produce C.C. output. Based upon Relay’s specifications, the combined
application of two instruments can conduct fast current switching test and provide large current verification,
including current withstanding value and current withstanding time so as to ensure Relay’s quality. 

GW instek PEL-3111 Programmable DC Electronic Load (150V, 210A, 1050W)

相关新闻

SUPERIOR hotspot detection capabilities with new technology from FLIR thermal cameras
2026年08月17日 16時35分56秒

A terminal lug inside an electrical cabinet may gradually heat up—a change almost imperceptible to the naked eye. A motor bearing begins to rise in temperature even before any abnormal noise occurs. These changes often manifest quite early, yet maintenance teams typically only begin investigating the cause once the equipment shuts down or a circuit breaker trips

Đừng vội báo giá ngay khi khách hàng đưa ra yêu cầu! Vì sao? Chia sẻ từ Best Sale EMIN
2026年08月17日 09時27分28秒

Vì đúng mẫu máy chưa chắc đã đúng nhu cầu. Bán một chiếc máy hiện sóng là đưa khách hàng một thiết bị, còn tư vấn đúng chiếc máy để tìm ra căn nguyên vấn đề của họ mới là phần việc thật sự của một người bán hàng kỹ thuật. Có lẽ đó cũng là lý do giúp anh Bảo giữ vị trí Best Sale EMIN Group năm 2025, không chỉ nhờ hiểu khách hàng, mà còn nhờ vốn kiến thức sâu về những sản phẩm Tektronix mà EMIN đang phân phối.

获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款隐私政策

快速支持

直接联系认证专家