Reliability Test for Relay Using GW PSW Power Supply and PEL-3111 E. Load

2017年12月19日 17時28分24秒

How do you conduct relay connection point (N.O. / N.C.) tests? How do you test the life cycle of relay’s connection point (N.O. / N.C.)?   How do you evalua

How do you conduct relay connection point (N.O. / N.C.) tests? How do you test the life cycle of relay’s connection
point (N.O. / N.C.)?   How do you evaluate the connection resistance of connection point (N.O. / N.C.) after multiple
tests? How do you evaluate the speed for operating connection point (N.O. / N.C.)? 

Relay, functioning to produce mechanical on-off movement by receiving electric signal to change electro magnet,
is often applied to control other electronic device via receiving electronic signal. Voltage exerted on relay’s coil
allows current to pass through coil and magnetizes core. Armature is then be pulled by core due to electromagnetic
force. Hence, a mechanical on-off movement is produced.  


As shown on the top diagram, PSW 30-108, Relay and PEL-3111 are connected by series. PEL-3111 is set to 80A
current sink. Each time, Relay’s NO-COM is closed, NO-COM is tested for its current reliability. In the meantime,
PSW 80-40.5 is utilized to output sequential power supply to produce control signal to control Relay’s NO-COM.

One GW Instek PSW 80-40.5 can meet the actual measurement requirements via planning Relay’s control signal.
It not only controls signal’s voltage, current, time and period, but also determines the number of operating cycle.
There are totally 20,000 steps and each step can be set from 50ms to 20 days. The number of cycle can reach
1 billion or infinite by different specifications. Relay’s control signal can only verify the mechanical characteristics
of NO-COM and NC-COM. For further electric characteristic verification of NO-COM and NC-COM, PSW 30-108
and PEL-3111 must be concurrently utilized to produce C.C. output. Based upon Relay’s specifications, the combined
application of two instruments can conduct fast current switching test and provide large current verification,
including current withstanding value and current withstanding time so as to ensure Relay’s quality. 

GW instek PEL-3111 Programmable DC Electronic Load (150V, 210A, 1050W)

相关新闻

Why Does a Type K Temperature Probe Become Less Accurate Over Time ?
2026年08月13日 14時41分25秒

A Type K temperature probe may gradually become less accurate after prolonged use due to aging, oxidation, and changes in the probe’s thermoelectric characteristics. The higher the temperature and the longer the exposure time, the more noticeable these effects can become.

Can a standard meter measure such a very small current?
2026年08月12日 10時58分58秒

Multimeters can still measure small currents, but only up to a certain limit. When the current drops to the µA or nA range—or lower—the device's resolution, background noise, and stability begin to directly affect the results. This is when a picoammeter or a specialized current-measuring instrument is required