直接联系认证专家

Inner dimensions: 60 × 80 × 85 cm (W × D × H)
Outer dimensions: 141 × 223 × 220 cm (W × D × H)
Temperature shock range: -40 ℃ ~ 125 ℃
Temperature change rate: 3 ℃ ~ 15 ℃ / min
Temperature cycling range: -40 ℃ ~ 85 ℃
Temperature change rate: 3 ℃ ~ 20 ℃ / min
Preheating time: RT ~ -70 ℃: 80 min
Dwell time: 30 min
Static load: 30 KG (MAX)
Temperature control stability: ±0.5 ℃ (no load) (control point)
Temperature ramp fluctuation: ±3.0 ℃ (no load) (control point)
Temperature uniformity: ±2 ℃
Special requirements:
A. -40 ℃ ↔ +85 ℃ (linear) 20 ℃ / min, dwell time 23 min;
B. Temperature overshoot control within SV value ±5 ℃;
C. After the PV at 9 points inside the chamber reaches SV, PV must enter within SV ±2 ℃ within 7 min;
D. During temperature ramp-up and ramp-down, temperature distribution at 9 points inside the chamber must be uniform, without large fluctuations.