直接联系认证专家

- Clamping Ø 40 mm
- Display: 4,000 counts
- Bargraph: 42 segments
- Range change: Automatic
- Function keys" Hold-Peak - Max/Min - ∆Rel -
- IEC 61010-1 and IEC 61010-2-032 safety norms" Cat.III, 600 V
- Operating temperature: 0 to 40°C (<70% HR)
- Storage temperature: -10 to 60°C (<80% HR)
- Power supply: 1 x 9 V 6 LF22
- Battery charge life: 36 h
- Auto cut-off: 30 min., deactivatable
- Dimensions: 246 x 93 x 43 mm/ Weight: 400 g
TECHNICAL SPECIFICATIONS
- AC current
+ Measuring range: 0.05 to 1000 A (in 3 calibres)
+ Basic accuracy: 1.9%L + 5D
+ Bandwidth: 50 Hz to 1 kHz
+ Protection: 1200 ARMS
- DC current
+ Measuring range 0.10 to 1000 A (in 3 calibres)
+ Basic accuracy: 2.5%L + 10D
+ Protection: 1200 A RMS
- AC voltage
+ Measuring range: 0.5 V to 750 V (in 2 calibres)
+ Basic accuracy: 2.5%L + 10D
+ Bandwidth: 50 Hz to 1 kHz
+ Input impedance: 10 MΩ
+ Protection: 1000 VRMS
- DC voltage
+ Measuring range: 0.2 to 1000 V (in 2 calibres)
+ Basic accuracy: 1%L + 2D
+ Protection: 1000 VRMS
- Resistance
+ Measuring range: 0.2 to 4000 Ω
+ Basic accuracy: 1%L + 2D
+ Max. open circuit voltage: 6 VDC
- Diode
+ Test current: 1.7 mA max.
+ Max. open circuit voltage: 6 VDC
- Continuity with buzzer
+ Detection threshold: ≤100 Ω
- Frequency
+ Measuring range :Current: 20 Hz to 10.00 kHz (in 2 calibres); Voltage: 10 Hz to 10 kHz (in 2 calibres
+ Basic accuracy: 0.1%L + 1D
+ Sensitivity: 2-5 A RMS/ 5-10 V RMS
Delivered with carrying bag containing:
a set of measuring leads, a carrying bag, a user's manual and one 9 V alkaline battery
Combining the basic functions of a multimeter and a Hall-effect current clamp for measuring DC and AC currents up to 1,000 A.
The use of an RMS converter ensures accurate measurements whatever the type or waveform of the signal.
It is extremely easy to grip and has a highly readable display.
MX655, specifications: