Withstanding Voltage: AC 1500V, 1 minute
Insulation Resistance: 10MΩ or more by DC 500V insulation tester (between detecting tip and earth clip)
Size and Weight: 129 (L)×20 (W)×19.5 (D)mm, approx. 30g
Operating Temperature: 0℃~40℃
Power supply: 1.55V (LR-44)×2
Power consumption: Approx. 60 hours continuous
Detectable voltage range(50/60Hz):
For insulation cover: AC 50~500V phase to earth
For bare terminal: AC 0~300V phase to earth
Minimum detectable voltage: AC40V (Factory setting) (Sensitivity is adjustable)