直接联系认证专家
CMRR: 86 dB
NMRR: 100 dB
Drift: Zero: ±20 μV/°C, Span: ±25 ppm/°C
Width: 72 mm
Height: 35 mm
Length: 123 mm
Memory: EEPROM: 16KB
Mounting: DIN-Rail or Wall Mount
Software: Built in: OME-WISE Firmware
Isolation: 2500 Vdc, 2-Way
Input Type: Voltage, Current
Configuration: 16-bit, SRAM: 512 KB, Flash Memory: 512KB
Output Signal: Digital
Data Interface: Ethernet
LED Indicators: PoE Power: PoE on, L1: System running, L2: Ethernet link/act, L3: Ethernet 10/100M speed
Supply Voltage: 12 to 48 Vdc
Analog I/O Note: Analog Input Note: Analog Input;Input Channels: 8 (differential); Input Type: ±150 mV, ±500 mV, ±1V, ±5V, ±10V;±20 mA, 0 to 20 mA, 4 to 20 mA (jumper selectable);Resolution: 16-bit;Sampling Rate: 10 sample/second (total);Accuracy: ±0.1%;Zero Drift: ±20 μV/°C;Span Drift: ±25 ppm/°C;Overvoltage Protection: 240 Vrms;Input Impedance;Voltage: 2 MΩ;Current: 125 MΩ;Common Mode Rejection: 86 dB minimum;Normal Mode Rejection: 100 dB;Individual Channel Configuration: Yes
Impedance Input: Voltage: 2 MΩ, Current: 125 MΩ
Digital I/O Note: Digital Output: Output Channels: 4 Output Type: Isolated open collector (sink) Maximum Load Current: 700 mA/channel Load Voltage: 5 to 50 Vdc Overvoltage Protection: 60 Vdc Overload Protection: 1.4 A Short-Circuit Protection: Yes
Electrical Output: Isolated open collector (Sink)
Power Consumption: 3.1 W
Relative Humidity: 10 to 90% RH, non-condensing
Software Settings: • Rule Configuration Website: Access Web server on OME-WISE-7000 controllers to edit and upload logic rules through web browser • 36 IF-THEN-ELSE Logic Rules: 3 IF conditions with AND or OR operators; 3 THEN actions; 3 ELSE actions • 48 Internal Registers: Hold temporary variables and read/write data via MODBUS/TCP address • 12 Timers: Delay/timing functions • 12 Emails: Send email messages to pre-setemail receivers • 12 CGI Commands: Send pre-set CGI commands • 12 Recipes: Set up THEN/ELSE action groups • 8 P2P Remote Modules: Set up the connection information for the remote OME-WISE-7000 modules • Rule Configuration Website: Access Web server on OME-WISE-7000 controllers to edit and upload logic rules through web browser • MODBUS/TCP Protocol: Real time control and monitoring I/O channels and system status of controllers via SCADA software"
Input Voltage Note: Absolute Maximum Input Voltage: Power on: 50 Vdc, Power off 4 Vdc
Data Interface Note: Ethernet Port: 10/100 Base-TX and automatic MDI/MDI-X with PoE (Power over Ethernet);Watchdog: Dual;Supported Operating System: MiniOS7;Web HMI: Yes, I/O Pair Connection: Yes
Storage Temperature, Max: 80 °C
Storage Temperature, Min: -30 °C
Current Measurement Range: ± 20 mA
Number of Channels, Input: Analog: 8 DIFF
Voltage Measurement Range: ±150 mV, ±500 mV, ±1V, ±5V, ±10V
Number of Channels, Output: Digital: 4
Operating Temperature, Max: 75 °C
Operating Temperature, Min: -25 °C