OMEGA PX409S20-500AUSBH 高精度卫生压力传感器 (Absolute, 500 psi, Tri-Clamp, 2 in)

ModelPX409S20-500AUSBH
联系我们
安全结算
品质保证
轻松更换与退货
支持配送

Shock: 50 g, 11 ms half sine (under test)

Weight: 285 g

Accuracy: ± 0.08 %

Bandwidth: DC to 1000 updates per second (± 3%)

Stability: ± 0.1%

Vibration: ± 20 g

Fill Fluid: NEOBEE M5 food grade

Accuracy Note: ± 0.08% best straight line (linearity, hysteresis and repeatability combined) compound gage models calibrated in positive direction only

Output Signal: Digital

Pressure Type: Absolute

Pressure, Max: 500 psi

Pressure, Min: 0 psi

Response Time: <1 ms

ADC Resolution: 24 bit

Accuracy Class: < 0.1%

Burst Pressure: 4x Full Scale to Maximum Rated Flange Pressure

Proof Pressure: 6x Full Scale up to 2000 psi

Pressure Cycles: 1 million, minimum

Electrical Output: USB

Enclosure Ratings: IP65

Materials, Wetted: 316L Stainless Steel

Zero/Balance Error: ± 0.5%

Additional Features 1: None

Electrical Connection: Cable

Insulation Resistance: 100 MΩ @ 50 Vdc case to sensor; 2 MΩ @ 50 Vdc case to output terminations

electrical-connection: Cable

Process Connection Note: 1 1⁄2" and 2" Tri-GripTM Fitting: 600 psi using suitable clamp

Process Connection Size: 2 in

Process Connection Type: Tri-Clamp

Shunt Calibration Value: 5-point NIST traceable calibration with zero and span values, calibrated in horizontal direction

Zero/Balance Error Note: ± 0.5% full scale typical ± 1% maximum (± 1% typical, ± 2% maximum for 5 psi and below)

Operating Temperature, Max: 95 °C

Operating Temperature, Min: -15 °C

Compensated Temperature, Max: 87.7 °C

Compensated Temperature, Min: -1.1 °C

Span Setting Adjustable Range: ± 0.5% FS

Thermal Effect on Span error, Max: 0.005, 0.005%/°F

Thermal Effect on Zero error, Max: 0.005%/°F, 0.005