直接联系认证专家
Weight: 600 g
Frequency: 40 to 63 Hz
Form factor: 22.5 mm DIN Rail
Power Cycle: Turn-On Time: 8.33 ms; Turn-Off Time: 8.33 ms
Current, Min: 100 mArms
Voltage, Max: 550 V
Control Output: Triac
Current Output: 10 A
Voltage Output: 24 to 280 Vac
Dropout Voltage: 1 Vdc
Horsepower Note: None
Leakage Current: 100 µArms
Wire Gauge Note: Input Strandard Wire Gauge: 24 to 16 AWG; Input Solid Wire Gauge: 24 to 16 AWG; Output Stranded Wire Gauge: 16 to 8 AWG; Output Solid Wire Gauge: 16 to 10 AWG
Housing Material: UL 940VD (self-extinguishing)
Input Resistance: Current Regulated
Number of Phases: 1
Signal fail-safe: 500 Vµs
Enclosure Ratings: IP20
Thermal Sensitivity: 340
Input Control Signal: 4 to 32 Vdc
Leakage Current Note: Off-State Leakage µArms (@ Max Line Voltage and Ta = 25ºC)@ 24 to 240 Vac
Surge Current Rating: 1 Cycle, Max: 100 A; 1 s, Max: 30 A
Operating Voltage, Min: 1.5 V
Isolated Analog Voltage: 4000 Vrms
Measurement Current, Max: 19 mA
Measurement Current, Min: 16 mA
Storage Temperature, Max: 100 °C
Storage Temperature, Min: -40 °C
Input-to-Output Capacitance: 8 pF
Input/Output-to-Ground Isolation: 4000 Vrms