直接联系认证专家
Impact energy: 0.14J | 0.2J | 0.35J | 0.5J | 0.7J | 1J
Test IK level: IK01 | IK02 | IK03 | IK04 | IK05 | IK06
Error: ±10%
Equivalent mass: 250g±5g
Radius of hammer: R10mm
Weight: 1250g
Trigger force: <10N
Material of hammer: Polyamide
Material of shell: Stainless steel
The universal spring hammer test apparatus is adjustable to perform IK01 (0.14J), IK02 (0.2J), IK03 (0.35J), IK04 (0.5J), IK05 (0.7J) and IK06 (1J) tests. It can meet the test requirements of IEC60068-2-75 and IEC62262. The universal spring hammer consists of the body, the striking element and the release system. The striking element is made of polyamide, and has an equivalent mass of 250g. The spring hammer can be used in any position providing there is enough space to apply it correctly.
Single operated spring hammer can be sold independently.