Output voltage (open): 0.2-10kV ±5%
Front time: 1.2μs ±30%
Time to half-value: 50μs ±20%
Output current (short): 5kA±5% (max)
Front time: 8μs ±20%
Time to half-value: 20μs ±20%
Output polarity: Positive, negative, positive/negative
automatically
Output impedance: 2Ω±10%, 500Ω±10%
Trigger mode: Synchronization, asynchronization
Inject phase: Freely set at 0-360°,resolution:1°
Trigger mode: Auto or manual, single
Surge times: 1-9999 times
Memories: 1000 groups, built in IEC standard
Surge interval: 30-9999s
Built in network capacity: 3 phase, 380V/20A
Coupling mode: L1-N,L2-N,L3-N, L1-PE,L2-PE,L3-PE,N-PE
Coupling device: 18μF capacitance (L-N), 10Ω resistor+9μF
capacitance (L-PE)
Working environment: Temperature:15°C-35°C humidity:10%-75%
Power supply: AC220±10%,50/60Hz
Lightning Surge Generator is a auto equipment designed according to IEC61000-4-5 and GB/T17626.5, and completely meet the requirements of the standards. It is widely used in the fields of industry control equipment, house-holding appliance, medical electronics, communications electronics,components, auto control equipment and etc.
Lightning surge generator is to simulate the surge voltage caused by switching transient and lightning transient, the surge test is to found out the surge voltage effect to EUT in normal working condition. This model can generate both 1.2/50, 8/20 µs combination wave. The test voltage is up to 10KV, user can choose and define the test levels. The parameters of waveform for surge voltage and waveform for surge current is strictly meet the standard requirements of IEC61000-4-5. The generator is built in a 380V/20A coupling and decoupling network.