Outer size (L*W*H): 1500*1900*2250 (mm)
Inner size (L*W*H): 1000*1000*1000 (mm)
Number of nozzle: 1pc
Nozzle position: Right side of inner chamber
Distance nozzle to device under test: (325±25) mm (munally
adjust)
High temperature range: RT +10℃~150℃
Heating rate: RT +10℃~150℃≤
45min
Splash water temperature: 0℃~+4℃
Cooling rate: +25℃~2℃≤
60min
Water flow: (3~4)L/3s
Test liquid: De-ionized water or +3% Arizona fine dust
Injection time per cycle (30min): 3s, interal time:29min57s
(touch screen setting)
Number of shocks (cycles): 100 cycles (touch screen setting)
Working power: 380V/50Hz (3 phase 4 wires+ protective
ground)
Power: 12.0KW
The splash water test chamber meets the requirement of ISO16750-4 clause 5.4.2. It can be used for splash water or high temperature test alone, to simulate ice water splashing over a hot system or components when driving on wet roads in the winter. Failure modes are mechanical cracking of materials or seal failures caused by different temperature expansion coefficients. I’ts a reliability testing equipment for cold resistance, heat resistance, ice water splash resistance test and quality control engineering of various electronic, electrical, plastic and other raw materials and devices.