Weight: 1 kg (2.2 lbs)

Cable entry details: 10 cable entry knockouts, 5 x M20, and 1 x M16 underside. 4 x PG11 at rear

Operating Temperature (Electronics): -20 °C to +50 °C (-4 °F to +122 °F)

Analog output: 2 x isolated (to 150 V floating) output of 4-20mA or 0-20mA into 1 kΩ (user-programmable and adjustable) 0.1% resolution

Digital output: Half-duplex RS232

Display: 192 x 128 pixel illuminated graphical display showing a variety of screens including echo profile. Fully programmable display options, integral keypad with menu navigation keys

PC Software: Sludge Finder PC within PC Software Suite - compatible with XP (service pack 3), Windows 7/8/10

Fuse: 2A slow blow

Operating Voltage: Universal 100-240 V AC 50/60 Hz, 22-28 V DC

Power Consumption: 20 W maximum power (typically 11 W)