Rated Voltage: 100kV
Maximum output current: 2 mA
Control Box Size: 310 × 250 × 230 mm
Control Box Weight: 6kg
High-Voltage Unit Size: 550 × 260 × 220 mm
High-Voltage Unit Weight: 8kg
Output polarity: Negative polarity, no-voltage start, linear continuous adjustment
Working power supply: 50Hz AC220V±10%
Voltage error: 0.5%±2, minimum resolution 0.1kV
Current error: 0.5%±2, minimum resolution 0.1µA
Ripple factor: Better than 0.5%
Voltage stability: Random fluctuation
Working manner: Interval working, less than 30 minutes under rated load
Working condition: Temperature: 0–40°C, humidity: <90%
Storage condition: Temperature: -10–40°C, humidity: <90%
Altitude: Lower than 3000m
Ⅳ: Features About The DC Hipot Cable Test:
1. Dc high voltage generator adopts high frequency PWM technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The generator can endure direct discharge by devices of large capacitance. It is of small size and of light weight, convenient for field use.
2. Over-voltage setting function displays the over-voltage value during regulation process; perfect protection against discharge of over-voltage, over-current and short circuit. This is the best companion for cable experiments.
3. Perfect break line and non-zero potential start protection function protects the operator and samples at any time. This product has overall design of shock-proof control box, concise, clear panel design and voice prompt for operation.
4. 75% MOA voltage switch button, simple and convenient testing arrester.
Ⅴ: Pay Attention for this Hipot Test Equipment:
1. Do not overload operation, not too fast lift pressure, continuous use time should not exceed 30 minutes.
2. If the subject is a cable, it needs to know the voltage level to determine the voltage and the cable length to determine the current.
3. When measuring lightning arrester, use microammeter to connect the cylinder high pressure line.