For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

ShinewayTech palmOTDR-P11C 掌上OTDR (1625 nm, basic model)

ModelpalmOTDR-P11C
联系我们
安全结算
品质保证
轻松更换与退货
支持配送

Model: Basic

Wavelength (±20nm): 1625(4)

Dynamic Range(2): 37dB

EDZ (m)(3): 0.8

ADZ (m)(3): 4.5

Pulse Width: 10ns, 30ns, 100ns, 300ns, 1µs@850nm; 10ns, 30ns, 100ns, 300ns, 1µs, 2.5µs@1300nm; 5ns, 10ns, 30ns,100ns, 300ns, 1µs,2.5µs, 10µs, 20µs@others

Averaging Time: Quick, 15s, 30s, 1min, 2min, 3min

Distance Measure Accuracy: ±(1m+5×10-5×distance+sampling space)

Attenuation Detect Accuracy: ±0.05dB/dB

Reflection Detect Accuracy: ±4dB

Data Storage: 1000 records

Connectivity: USB

Connector: FC/PC (Interchangeable SC, ST; optional LC)

Power Supply: NiMH Battery / AC Adapter

Battery Life: 8 hrs continuous operation, 20 hrs standby (on one charge); recharging time < 4 hrs

Operating Temperature: -20°C to 50°C

Storage Temperature: -40°C to 70°C

Relative Humidity: 0 to 95% (non-condensing)

Weight: 1kg (2.2 lbs)

Dimensions (H×W×T): 220×110×70mm (8.7×4.3×2.7 inch)

Functional Module Specifications: 

Visible Fault Locator Module(5): 

Wavelength (±20nm): 650nm

Output Power (dBm): ≥-3

Max Measurement Range: 5 Km


Stabilized Laser Source Module(5): 

Wavelength (±20nm): Same as OTDR working wavelength(5)

Output Power (dBm): ≥-7


Optical Power Meter Module(5): 

Calibrated Wavelength (nm): 850,1300,1310,1490,1550,1625

Power Range (dBm): -70 to +6 (-60 to +6 @ 850nm)

Detector Type: InGaAs

Display Resolution: 0.01dB

Accuracy: ± 5% ± 0.01nW (±0.5dB@850nm)

MOD Identification: 1K, 2K Hz


PON Power Meter Module(6): 

Calibrated Wavelength: 1310nm

Measurement Range (dBm): -40 to +8(Burst mode: -30 to +8)

Spectral Passband (nm): 1310±40


Calibrated Wavelength: 1490nm

Measurement Range (dBm): -40 to +8

Spectral Passband (nm): 1490±10


Calibrated Wavelength: 1550nm

Measurement Range (dBm): -40 to +20

Spectral Passband (nm): 1550±10

Power Uncertainty (dB): ≤ 0.5

Display Resolution (dB): 0.01

Insertion Loss (dB): ≤ 1.5

Threshold: 60 user-definable threshold sets

Data Storage: 1200 records


MCI100 Optical Connector Inspector Module: 

Zoom: 250X

Resolution: 0.75μm

Focus: Manual

Adaptor: 

 Standard:

25-U-M: FC/SC/ST/E2000 UPC male;

125-U-M: LC/MU UPC male;

25-U-F: FC/SC/ST/E2000 UPC female;

LC-U-F: LC  UPC female;

Optional:

125-A-M: LC/MU APC male;

25-A-M: FC/SC/ST/E2000 APC male;

SC-A-F: SC APC female;

FC-A-F: FC APC female;

LC-A-F: LC APC female;

* Specifications subject to change without notice


Notes:

(1) Specifications describe the instrument’s warranted performance, measured with typical PC-type connectors. Uncertainties due to the refractive index of fiber are not considered.

(2) The dynamic range is measured at maximum pulse width and averaging time of 3 minutes.

(3) Conditions for dead zone measurement: Reflection event is at 0.6Km, reflection intensity is less than -45dB, event dead zone is

measured with pulse width of 10ns; attenuation dead zone is measured with pulse width of 10ns.

(4)  1625nm can be replaced by 1650nm.

(5)  Visible fault locator module, Stabilized laser source module and Optical power meter module is standard on -VPSI models. Stabilized laser source shares palmOTDR optical port and work on the same working wavelength of palmOTDR.

(6)  PON power meter module is standard on P11C and P31C.


Order Information

Standard Package Includes:

Instrument, FC/PC connector, NiMH battery, TraceManager software CD, USB Data cable, AC adaptor, Soft carrying case, Warranty card, Certificate of calibration, Quick reference guide.

Datasheet

获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款隐私政策

快速支持

直接联系认证专家