Output capacity: 45KVA
AC input
Phase number: Three phases
Waveform: SINEWAWE
Voltage: 380V±10%
Frequency fluctuation range: 50HZ or 60HZ±15%
Power factor ﹥0.8
AC output
Phase number: Single phase
Waveform: SINEWAWE
Low gear voltage: 0-150V continuously adjustable
High gear voltage: 0-300V continuously adjustable
Frequency: 50Hz, 60Hz, 40-499.9HZ continuously adjustable
Frequency stability: ≤0.01%
High grage maximum current (A): 187A (150-300V)
Low grade maximum current (A): 375A (0-150V)
Whole machine performance
Power regulation rate: ﹤1%
Load regulation rate: ﹤1%
Waveform distortion: ﹤2%
Efficiency: ﹥85%
Response time: ≤2ms
Crest Factor: 3:1
Protection device: With multiple protections such as overvoltage, overcurrent, overload, input undervoltage, overtemperature, short circuit, etc.
Display
Display interface: Digital LED display
Voltage: 4 digits, digital voltmeter, resolution 0.1V
Current: 4 digits, digital ammeter, resolution 0.1A
Power: 4-digit, digital wattmeter
Frequency: 4-digit number, digital frequency meter
Environmental and others
Cooling unit: High speed variable frequency fan cooling, forced cold air
Working temperature: -15℃~50℃
Relative humidity: 0~90℃ (non-condensing state)
Altitude: ≤1500m