Light source: Halogen
Setting range: F-number selection – 12 types (F1.4–F32), AUTO; SENS switching – 4 systems (SENS1–SENS4)
Accuracy [%]: Measurement accuracy within ±3%
Collimator optical system: Parallel light lens diameter 100 mm
Subject to inspection:
・Aperture of a lens shutter camera
・Aperture of a focal plane shutter camera
・Lens aperture of an interchangeable lens (requires a jig)
・Aperture diameter when the sync contact of a lens shutter camera is in contact (or when the flash is fired)
・Aperture after the set time from the EXIT signal
Measurement items: Aperture error (dEV) relative to reference light intensity; Aperture error (△EV) ±2EV
Measurement range: -2.02 to +2.02 EV
Measurement method:
The amount of light passing through the aperture, after the object is irradiated with parallel light, is converted into an electric signal by a photoelectric element, and the ratio to the light amount of the amplified reference aperture is converted into an EV value.
Display / Operation:
・Main unit operation
・External communication control (serial)
Communication I/F: USB 2.0 or RS-232C compliant
Power supply voltage: AC100–240V, 50/60Hz
Power consumption [VA]: 40
Dimensions (WxHxD) [mm]: 470×950×380
Weight [kg]: 13