For full functionality of this site it is necessary to enable JavaScript.
EMIN.VN
0
Product image

Wrindu RD9914B Insulation Withstand Voltage Tester (0.05kV~5.00kV AC, 0.05~6.00kV DC)

联系我们
安全结算
品质保证
轻松更换与退货
支持配送

AC withstand voltage test:

- Output voltage: AC: 0.05kV~5.00kV

- Maximum output capacity: 500VA (5.0kV 100mA)

Maximum rated current: 100mA

Output waveform: Sine wave, DDS+

DC Withstand voltage test:

- Output voltage: DC:0.05~6.00kV

- Maximum output capacity: 300VA (6.0kV 50mA)

Insulation resistance test:

- Output voltage: DC: 0.05kV-5.0kV

- Measuring resistance:

Range: 0.1MΩ-100GΩ

Precision: ≥500V: 

+ 0.10MΩ-1.0GΩ   ±5%

+ 1.0GΩ-50.0GΩ   ±10%

+ 50.0 GΩ-100.0GΩ     ±15%

+ <500V: 0.10MΩ-1.0GΩ  ±10%

+ 1.0GΩ-10.0GΩ  ±15%

Voltmeter:

Test range: AC:0.05 ~ 5.00 kV, DC: 0.05 ~ 6.00 kV

Test accuracy: ± (1%+3 digits)

Ammeter:

Test range: AC: 0~100mA, DC: 0~50mA

Test accuracy: ± (1%+2 digits)

Timer

Range: 0.0-999.9S

Minimum resolution: 0.1S

Testing time: 0.1S-999S, OFF = Continuous testing

Arc detection: 0-20mA

Output frequency: 50Hz/60Hz

Communication interface: RS-232C、USB、PLC

Display: 7-inch TFT 800*480

Power supply: 110V/220V, 50/60Hz


Product features
1. 7-inch TFT (800*480) is adopted to display setting and testing parameters. It’s large current and capacity makes the display content rich and eye-catching.
2. The stored data can be copied via USB interface.
3. The high voltage rise and fall time can be adjusted to meet the requirements of different test objects
4. Test results can be saved simultaneously.
5. User-friendly operation interface supports digital button input and dial input. The operation is simpler.
6. Minimum resolution of DC current is 0.001μA.
7. The PLC interface, RS232 interface and USB interface are its standard configuration.

获取优惠更新

获取专属批量折扣、批发价格更新和新产品通知,直接发送到您的邮箱。

订阅即表示您同意我们的服务条款隐私政策

快速支持

直接联系认证专家