For full functionality of this site it is necessary to enable JavaScript.

Advanced Energy UltraVolt 30LE 电源转换器 (30000VDC)

- High Voltage Output Range (Adjustable Regulated, Positive or Negative Output): 0 ~ 30000VDC
- High Voltage Outputs: Single Unipolar
- Input Voltage: Nominal, 24 VDC
- Power Output (Watts, Nominal): 4 W, 15 W, 30W
DC Input
- Vin (Input Voltage) Range: 23 ~ 30VDC
- Iin (Nominal):
100% HVout, 100% LOAD: 0.5A, 1.1A, 1.8A
100% HVout, 0% LOAD: < 0.3A
Disable/standby state: < 0.08A
DC Output
- Iout (Output Current): (max) @ 0~ 100% HVout, Vin (nominal), 0.13mA, 0.50mA, 1.00mA
- Pout (Output Power): max, 4W, 15W, 30W
- Ripple @ Full LOAD, Max Eout: <0.002%
Stability and Regulation
- Stability:
0.01% (100 ppm) @ 100% HVout (per 8 h interval, after 30 min warmup)
- Line Regulation: 0.0025% (25 ppm) @ 100% HVout, 100% Pout
- Static Load Regulation: 0.0025% (25 ppm) @ 100% HVout, Load Step, 0 ~ 100%
- Temperature Coefficient: 25 ppm/°C (standard configuration over operating temperature range)
- Power-On Rise Time:
< 750 msec @ 100% LOAD
Contact factory for other options.
Environmental
- Operating Temperature Range: 10 ~ 45°C (50 ~ 113°F) case temperature @ 100% HVout, 100% LOAD
- Storage: -55 ~ 105°C (-67 ~ 222°F) case temperature
- Humidity: 0 ~ 95% RH, non-condensing
- Altitude: Sea level to 2000 m (6562 ft)
- Certifications: UL/cUL recognized, IEC-62368-1, CE mark (LVD and RoHS)
Volumes and Weights:
- Volume (Module body only): 705cm3, 43in3
- Weight (Standard Configuration): 1322g, 46.6oz
Options & Accessories:
- -10PPM: Upgrades module temperature coefficient rating from 25 ppm/°C to 10 ppm/°C for enhanced high-voltage output stability over standard
operating temperature ranges.
- -AZ: Enhances the stability of module high voltage output at setpoints below <10% HVout by optimizing performance. (Available only on 4 W models).
- -DAF: Replaces male DA-15 Type connector at with female DA-15 Type connector to ease system retrofit and integration tasks
- -LGH: Replaces standard front panel HVout flying lead and ground stud with rear panel mounted LGH Type 1/2L conn
- -SHV: Replaces standard front panel HVout flying lead and ground stud with rear panel mounted SHV-5KV connector and ground stud. (Available only on 1 to 4 kV units).
- -BNC: Replaces standard front panel HVout flying lead and ground stud with rear panel mounted BNC-10KV connector and ground stud. (Available only on 1 to 10 kV units)