For full functionality of this site it is necessary to enable JavaScript.

Advanced Energy UltraVolt 4LE 标准尺寸高压电源 (4000VDC,30W)

- High Voltage Output Range (Adjustable Regulated, Positive or Negative Output): 0 ~ 4000VDC
- High Voltage Outputs: Single Unipolar
- Input Voltage: Nominal, 24 VDC
- Power Output (Watts, Nominal): 4 W, 20 W, 30W
DC Input
- Vin (Input Voltage) Range: 23 ~ 30VDC
- Iin (Nominal):
100% HVout, 100% LOAD: 0.4A, 1.4A, 1.7A
100% HVout, 0% LOAD: < 0.325A
Disable/standby state: < 0.08A
DC Output
- Iout (Output Current): (max) @ 0~ 100% HVout, Vin (nominal), 1mA, 5mA, 7.5mA
- Pout (Output Power): max, 4W, 20W, 30W
- Ripple @ Full LOAD, Max Eout: 50mV
Stability and Regulation
- Stability:
0.01% (100 ppm) @ 100% HVout (after 30 min warmup interval)
0.02% (200 ppm) @ 100% HVout (per 8 h interval)
- Line Regulation: 0.0025% (25 ppm) @ 100% HVout, 100% Pout
- Static Load Regulation: 0.0025% (25 ppm) @ 100% HVout
- Temperature Coefficient:
25 ppm/°C (standard configuration over operating temperature range)
10 ppm/°C (with -10PPM option over operating temperature range)
- Power-On Rise Time:
< 750 msec @ 100% LOAD
Contact factory for other options.
Environmental
- Operating Temperature Range: 10 ~ 45°C (50 ~ 113°F) case temperature @ @ 100% HVout, 100% LOAD
- Storage: -55 ~ 105°C (-67 ~ 222°F) case temperature
- Humidity: 0 ~ 95% RH, non-condensing
- Altitude: Sea level to 3000 m (10,000 ft)
- Certifications: UL/cUL recognized, IEC-60950-1, CE mark (LVD and RoHS)
Volumes and Weights:
- Volume (Module body only): 562cm3, 34.3in3
- Weight (Standard Configuration): 912g, 32.1oz
Options & Accessories:
- -10PPM: Upgrades module temperature coefficient rating from 25 ppm/°C to 10 ppm/°C for enhanced high-voltage output stability over standard
operating temperature ranges.
- -AZ: Enhances the stability of module high voltage output at setpoints below <10% HVout by optimizing performance. (Available only on 4 W models).
- -DAF: Replaces male DA-15 Type connector at with female DA-15 Type connector to ease system retrofit and integration tasks
- -LGH: Replaces standard front panel HVout flying lead and ground stud with rear panel mounted LGH Type 1/2L conn
- -SHV: Replaces standard front panel HVout flying lead and ground stud with rear panel mounted SHV-5KV connector and ground stud. (Available only on 1 to 4 kV units).
- -BNC: Replaces standard front panel HVout flying lead and ground stud with rear panel mounted BNC-10KV connector and ground stud. (Available only on 1 to 10 kV units)

Details

Datasheet

  • 质量承诺
  • 正品保修
  • 送货到家
  • 交易简单化