For full functionality of this site it is necessary to enable JavaScript.

Ainuo AN29203(F)交直流电子负载(4200W; 30A)

Max. Power: 4200W
Max. Voltage: 260V
Max. Current: 
Working Frequency:  DC,40~440Hz 
1) Working Mode
+ Constant Current:  0.10~30A ; DC/50/60Hz:±(0.5% of setting + 0.3 % of measurement); 400Hz: ±(1.0 % of setting + 0.5% of measurement)
+ Constant Resistance:  1~130Ω ; DC/50/60Hz:±(1.5% of setting + 0.5 % of measurement); 400Hz: ±(1.5 % of setting + 1.0% of measurement)
+ Constant Power: 10W~4200W; DC/50/60Hz:±(1.5% of setting + 0.5 % of measurement); 400Hz: ±(2 % of setting + 1.0% of measurement)
2) Test
+ Voltage: 0~260V; DC/50/60Hz:±(0.5% of setting + 0.1 % of measurement); 400Hz: ±(0.5 % of setting + 0.1% of measurement)
+ Current: 0~30.00A; DC/50/60Hz:±(0.5% of setting + 0.2 % of measurement): 400Hz: ±(1.0 % of setting + 0.5% of measurement)
+ Power: 10W~4200W; DC/50/60Hz:±(1.5% of setting + 0.5 % of measurement); 400Hz: ±(2% of setting + 1.0% of measurement)
3) Protection
+ Input Over Voltage: Max. 105%
+ Input Over Current: Max. 105%
+  Input Over Power: Max. 105%
+ Over Temperature: 85℃
4) Dimension: 482*356*460
5) Trọng lượng: 58 kg

Details

 

Product Detail

With Basic working mode of constant current, constant resistance and constant power

Widely used in simulation tests for inverters such as transformer, UPS, AC inductive and capacity and rectification capacitive load

Model No.

AN29201F

AN29202F

AN29203F

AN29204F

Working Conditions

Working Power Supply

AC 220V±10%50/60Hz±5%

Environment Temperature

040

Relative Humidity

2090RH40

Measurement

Max. Power

1400W

2800W

4200W

5600W

Max. Voltage

260V

Max. Current

10A

20A

30A

40A

Working Frequency

DC,40440Hz

Working Mode

Constant
Current

Measurement

0.1010A

0.1020A

0.1030A

0.1040A

Resolution

10mA

Allowed Maximum Error

DC/50/60Hz:±(0.5% of setting + 0.3 % of measurement)
400Hz: ±(1.0 % of setting + 0.5% of measurement)

Constant
Resistance

Measurement

1400Ω

1200Ω

1130Ω

1100Ω

Resolution

0.1 /1Ω

Allowed Maximum Error

DC/50/60Hz:±(1.5% of setting + 0.5 % of measurement)
400Hz: ±(1.5 % of setting + 1.0% of measurement)

Constant
Power

Measurement

10W~1400W

10W~2800W

10W~4200W

10W~5600W

Resolution

1W

Allowed Maximum Error

DC/50/60Hz:±(1.5% of setting + 0.5 % of measurement)
400Hz: ±(2 % of setting + 1.0% of measurement)

Test

Voltage

Measurement

0~260V

Resolution

100mV

Allowed Maximum Error

DC/50/60Hz:±(0.5% of setting + 0.1 % of measurement)
400Hz: ±(0.5 % of setting + 0.1% of measurement)

Current

Measurement

0~10.00A

0~20.00A

0~30.00A

0~40.00A

Resolution

10mA

Allowed Maximum Error

DC/50/60Hz:±(0.5% of setting + 0.2 % of measurement)
400Hz: ±(1.0 % of setting + 0.5% of measurement)

Power

Measurement

10W~1400W

10W~2800W

10W~4200W

10W~5600W

Resolution

1W

Allowed Maximum Error

DC/50/60Hz:±(1.5% of setting + 0.5 % of measurement)
400Hz: ±(2% of setting + 1.0% of measurement)

CurrentPhaseshift Angle

Setting Range

±90°

Current Waveform Simulation

Peak Factor Setting Range

1.45

Trigger Phaseshift Range

(0°) (360°)

Dynamic
Characteristics

Load On Time Setting Range

5ms10s

Load On Time Setting Error

Max. 10us

Protection

Input Over Voltage

Max. 105

Input Over Current

Max. 105

Input Over Power

Max. 105

Over Temperature

85

Dimension

482*223*460 (W×H×D)

482*356*460

WeightKg

33

43

58

68

Optional Accessories

RS232, RS485, GPIB, USB, Net gape, Single/ 3-phase Online and I-Monitor Interface

                   

 

 