For full functionality of this site it is necessary to enable JavaScript.

Artesyn LPS65-M 开放式机架低功率AC-DC电源 (24V; 60-80W)

Input

Input range: 85 - 264 Vac (wide range); 120 - 300 Vdc

Frequency: 47 - 440 Hz

Inrush current: < 18 A peak @ 115 Vac; < 36 A peak @ 230 Vac, cold start @ 25°C

Input current: 1.5 A max. (RMS) @ 115 Vac

Efficiency: 70% typical at full load 

EMI filter: FCC Class A conducted; CISPR 22 Class A conducted EN55022 Class A conducted; VDE 0878 PT3 Class A conducted

Safety ground leakage current: < 75 μA  @ 50/60 Hz, 264 Vac input

Output

Maximum power: 60 W for convection; 80 W with 30CFM forced air 

Adjustment range: -5, +10% minimum

Hold-up time: 20 ms @ 60 W load, 115 Vac nominal line

Overload protection: Short circuit protection on all outputs. Case overload protected @ 110% to 145% above peak rating

Overvoltage protection: 5V output; 5.7 to 6.7 VDC. Other outputs 10% to 25% above nominal output

Remote sense: Compensates for 0.5 V lead drop min. Will operate without remote sense connected. Reverse connection protected.

Environmental Specifications

Operating temperature: 0°C to 50°C ambient derate each output at 2.5% per degree from 50°C to 70°C, -20°C start up.

Electromagnetic susceptibility: Designed to meet IEC61000-4-2, -4-3, -4-4, -4-5, -4-6, Level 3

Humidity: Operating; non-condensing 5% to 95% RH

Vibration: Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four major resonances 0.75 G peak 5 Hz to 500 Hz, operational

Storage temperature: -40°C to +85°C

Temperature coefficient: ±0.04% per °C

MTBF demonstrated: > 550.000 hours at full load and 25°C ambient conditions

Ordering Information

Output Voltage: 24 V

Minimum Load: 0 A

Maximum Load with Convection Cooling: 2.5 A

Maximum Loadwith 30CFM Forced Air: 3.3 A

Peak Load:3.8 A

Regulation: ±2%

Ripple P/P(PARD): 240 mV


Details

Datasheet 

  • 质量承诺
  • 正品保修
  • 送货到家
  • 交易简单化

注册收新闻 - 获得优惠活动的机会