BIOBASE BK-800(EMERALD)自动化学分析仪
制造商: BIOBASE Model: BK-800(EMERALD) 来源: China 保障: 12 Month - 报价要求
- 联系
Manufacturer: BIOBASE
Model: BK-800(EMERALD)
Origin: China
Warranty: 12 months
Features: 150 Sample positions; 160 Reaction cuvettes; 180 Refrigerated reagent positions; Optical filter/fiber bragg grating selectable; 800 Tests per hour 1200 Tests with ISE module
Type:Random, Discrete, fully automatic
Test Speed:5800T/H, 1200T/H with ISE
Analysis Method:End-point, Fixed-time, Rate, Two-points, Turbidimetry
Programming Items: Programmable for any test items
Sample unit
Sample Settings: 150 sample positions, including 60 refrigerated positions for calibrator&QC, dual tray
Sample Tubes: Original blood collection tube, micro tube, plastic tube, etc
Sample Types : Serum, plasma, urine, CFS, etc
Sample Volume: 2ul ~70ul (0.1ul stepping)
Sample Probe: Liquid level detection function; anti-collision function
Probe Washing: Automatically wash interior and exterior, ross contamination rate <0.1%
Analysis Items: Analyzing maximally 100 items at the same time
Reagent unit
Reagent Position: 180 refrigerated reagent positions; dual tray
Wash Solution: Washing solution can be installed in any position, including needle, stir bar washing solution and water bath disinfectant
Reagent Volume: 20~350μl (1μl stepping)
Temperature Control: 2°C~8°C cooling for 24 hours
Reagent Probe: Liquid level sensor function; anti-collision function
Probe cleaning: Automatically wash interior and exterior
Reaction unit
Reaction Volume: 150ul~550ul Reaction Temperature 37℃
Temperature System: Water bath, real-time temperature display
Cuvettes : 160 positions, PMMA cuvette (optical path length 5mm)
Mixer Probe : Independent stir bar, nanotechnology, highly polished, automatic frequency conversion
Washing : Automatic water cleaning and drying system
System Adjustment: System can record the blank value and get more accurate result by deducting blank base value of each cuvette
Light Source:Halogen lamp (Grating optional)
Receiver : Holographic flat field concave grating diode array detection
Wavelength Range: 12 wavelengths from 340 to 800nm
Linear Range: -0.3~3.3 Abs
Stray Light:<0.1% or Abs >3.0
STAT Function:Emergency samples can be placed in the sample tray at any time
Computer System: Windows 7/8/10, LIS system available
Online: Full bi-directional communication possible
Data Processing: Reaction curve and data display function
Water consumption: Deionized water<25L/H
Power Supply :AC110/220V±10%, 60/50Hz
Package Size: 1718*929*1434mm
Gross Weight: 340kg