Rang:
3 mA /0.001 mA /1% + 5 dgt
30 mA /0.01 mA /1% + 5 dgt
30 A /0.01 A /1% + 5 dgt
60 A /0.1 A /5% + 5 dgt
Digital display: 3200 counts
Bar-graph display: 32 segments, LCD
Withstanding voltage: 3.7 kV ac
Battery type: 1 x 3 V Lithium battery CR2032
Diameter of measurable conductor: 40 mm max.
Weight: 200 g
Dimension: 176 mm x 70 mm x 25 mm
Included: Soft carrying pouch, Users manual
Manufacturer: Fluke
Made in Japan
Details
Method of detection |
|
Display |
Digital display: |
3200 counts |
Bar-graph display: |
32 segments, LCD |
|
Measurement Cycle |
|
2 times/second (Digital display), 12 times/second (Bar-graph display) |
|
Range switching |
|
Ambient temperature and humidity |
|
0 °C to 50 °C, 80 % RH or less (no condensation) |
|
Temperature coefficient |
|
0.05% of range/°C or less (within the ranges of 0 °C to 18 °C and 28 °C to 50 °C for measurement of 0-50 A) |
|
Influence of external magnetic field |
|
Influence of conductor position |
|
Circuit voltage |
|
Safety standard |
|
EN 61010-1, EN 61010-2-032, 300 V CAT III, Pollution Degree 2 |
|
Withstanding voltage |
|
Battery type |
|
1 x 3 V Lithium battery (button cell) CR2032 |
|
Battery life |
|
Approx. 90 hours (when continuously used) |
|
Auto power-off |
|
Diameter of measurable conductor |
|
Weight |
|
Dimension |
|
Operating altitude |
|
Electrical Specification |
Specifications at |
|
Accuracy |
|
(% readout + value of least significant digit) |
|
3 mA |
|
Resolution: 0.001 mA Accuracy: 1% + 5 Max Permissible current: 60 A rms |
|
30 mA |
|
Resolution: 0.01 mA Accuracy: 1% + 5 Max Permissible current: 60 A rms |
|
30 A |
|
Resolution: 0.01 A Accuracy: 1% + 5 Max Permissible current: 60 A rms |
|
60 A |
|
Resolution: 0.1 A Accuracy: 5% + 5 Max Permissible current: 60 A rms |
|
Datasheet »